- Spectral calibration of the fluorescence telescopes of the Pierre Aug…
Počet záznamů: 1  

Spectral calibration of the fluorescence telescopes of the Pierre Auger observatory

  1. 1.
    SYSNO ASEP0484992
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevSpectral calibration of the fluorescence telescopes of the Pierre Auger observatory
    Tvůrce(i) Aab, A. (NL)
    Abreu, P. (PT)
    Aglietta, M. (IT)
    Blažek, Jiří (FZU-D) ORCID, RID
    Boháčová, Martina (FZU-D) RID, ORCID
    Chudoba, Jiří (FZU-D) RID, ORCID
    Ebr, Jan (FZU-D) RID, ORCID
    Juryšek, Jakub (FZU-D) ORCID
    Mandát, Dušan (FZU-D) RID, ORCID
    Palatka, Miroslav (FZU-D) RID, ORCID, SAI
    Pech, Miroslav (FZU-D) RID, ORCID
    Prouza, Michael (FZU-D) RID, ORCID
    Řídký, Jan (FZU-D) RID, ORCID
    Schovánek, Petr (FZU-D) RID, ORCID
    Trávníček, Petr (FZU-D) RID, ORCID
    Vícha, Jakub (FZU-D) RID, ORCID
    Celkový počet autorů404
    Zdroj.dok.Astroparticle Physics. - : Elsevier - ISSN 0927-6505
    Roč. 95, Oct (2017), s. 44-56
    Poč.str.13 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovaAuger observatory ; nitrogen fluorescence ; extensive air shower ; calibration
    Vědní obor RIVBF - Elementární částice a fyzika vys. energií
    Obor OECDParticles and field physics
    CEPLM2015038 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LG15014 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    EF16_013/0001402 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000413280800004
    EID SCOPUS85029600900
    DOI https://doi.org/10.1016/j.astropartphys.2017.09.001
    AnotaceWe present a novel method to measure precisely the relative spectral response of the fluorescence telescopes of the Pierre Auger Observatory. We used a portable light source based on a xenon flasher and a monochromator to measure the relative spectral efficiencies of eight telescopes in steps of 5 nm from 280 nm to 440nm. Each point in a scan had approximately 2nm FWHM out of the monochromator. Different sets of telescopes in the observatory have different optical components, and the eight telescopes measured represent two each of the four combinations of components represented in the observatory. We made an end-to-end measurement of the response from different combinations of optical components, and the monochromator setup allowed for more precise and complete measurements than our previous multi-wavelength calibrations. We find an overall uncertainty in the calibration of the spectral response of most of the telescopes.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2018
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.