Počet záznamů: 1
Spectral calibration of the fluorescence telescopes of the Pierre Auger observatory
- 1.
SYSNO ASEP 0484992 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Spectral calibration of the fluorescence telescopes of the Pierre Auger observatory Tvůrce(i) Aab, A. (NL)
Abreu, P. (PT)
Aglietta, M. (IT)
Blažek, Jiří (FZU-D) ORCID, RID
Boháčová, Martina (FZU-D) RID, ORCID
Chudoba, Jiří (FZU-D) RID, ORCID
Ebr, Jan (FZU-D) RID, ORCID
Juryšek, Jakub (FZU-D) ORCID
Mandát, Dušan (FZU-D) RID, ORCID
Palatka, Miroslav (FZU-D) RID, ORCID, SAI
Pech, Miroslav (FZU-D) RID, ORCID
Prouza, Michael (FZU-D) RID, ORCID
Řídký, Jan (FZU-D) RID, ORCID
Schovánek, Petr (FZU-D) RID, ORCID
Trávníček, Petr (FZU-D) RID, ORCID
Vícha, Jakub (FZU-D) RID, ORCIDCelkový počet autorů 404 Zdroj.dok. Astroparticle Physics. - : Elsevier - ISSN 0927-6505
Roč. 95, Oct (2017), s. 44-56Poč.str. 13 s. Forma vydání Tištěná - P Jazyk dok. eng - angličtina Země vyd. NL - Nizozemsko Klíč. slova Auger observatory ; nitrogen fluorescence ; extensive air shower ; calibration Vědní obor RIV BF - Elementární částice a fyzika vys. energií Obor OECD Particles and field physics CEP LM2015038 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LG15014 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy EF16_013/0001402 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Institucionální podpora FZU-D - RVO:68378271 UT WOS 000413280800004 EID SCOPUS 85029600900 DOI https://doi.org/10.1016/j.astropartphys.2017.09.001 Anotace We present a novel method to measure precisely the relative spectral response of the fluorescence telescopes of the Pierre Auger Observatory. We used a portable light source based on a xenon flasher and a monochromator to measure the relative spectral efficiencies of eight telescopes in steps of 5 nm from 280 nm to 440nm. Each point in a scan had approximately 2nm FWHM out of the monochromator. Different sets of telescopes in the observatory have different optical components, and the eight telescopes measured represent two each of the four combinations of components represented in the observatory. We made an end-to-end measurement of the response from different combinations of optical components, and the monochromator setup allowed for more precise and complete measurements than our previous multi-wavelength calibrations. We find an overall uncertainty in the calibration of the spectral response of most of the telescopes.
Pracoviště Fyzikální ústav Kontakt Kristina Potocká, potocka@fzu.cz, Tel.: 220 318 579 Rok sběru 2018
Počet záznamů: 1