Počet záznamů: 1
On the recirculation zone suppression behind HUMP profile using the DBD actuator
- 1.
SYSNO ASEP 0483221 Druh ASEP C - Konferenční příspěvek (mezinárodní konf.) Zařazení RIV D - Článek ve sborníku Název On the recirculation zone suppression behind HUMP profile using the DBD actuator Tvůrce(i) Procházka, Pavel P. (UT-L) RID, ORCID, SAI
Uruba, Václav (UT-L) RID, ORCIDČíslo článku UNSP 02095 Zdroj.dok. EPJ Web of Conferences, EXPERIMENTAL FLUID MECHANICS 2016 (EFM16 ), 143. - CEDEX : E D P SCIENCES, 2017 - ISSN 2100-014X Poč.str. 6 s. Forma vydání Online - E Akce EFM16 – Experimental Fluid Mechanics 2016 Datum konání 15.11.2016 - 18.11.2016 Místo konání Mariánské Lázně Země CZ - Česká republika Typ akce WRD Jazyk dok. eng - angličtina Země vyd. FR - Francie Klíč. slova DBD actuator ; Hump profile ; flow control ; PIV Vědní obor RIV BK - Mechanika tekutin Obor OECD Fluids and plasma physics (including surface physics) CEP GP14-25354P GA ČR - Grantová agentura ČR TA04020129 GA TA ČR - Technologická agentura ČR TA04011437 GA TA ČR - Technologická agentura ČR Institucionální podpora UT-L - RVO:61388998 UT WOS 000407743800097 EID SCOPUS 85020075993 DOI https://doi.org/10.1051/epjconf/201714302095 Anotace Previously, the DBD (dielectric barrier discharge) plasma actuator was used in rectangular channel to modify the properties of the boundary layer in spanwise and in streamwise orientation. The actuator was redesigned for using on the surface of the Glauert-Goldschmied body in different position to influence the point of the separation and the reattachment point as well as the total extent of the separation bubble. The most intensive effect occurs when the actuator takes effect in the point of separation. Further downstream, the ionic wind produced by DBD causes complex coherent structures in the wake for spanwise orientation in both direction. The effect of streamwise orientation is studied also. Actuator is operated in steady regime to produces continuous ionic wind as well as in unsteady regime when the vortex street is generated. The properties of vortex street is given by modulation parameters (frequency and duty cycle). The effect of these parameters on the wake is evaluated. This experiment is realized in the perspex channel connected to the blow-down wind tunnel. The HUMP profile is flush-mounted to the bottom side. The wire electrode of the actuator is situated in x/L = 0.63, 0.66, 0.69 and 0.72 of the chord length. The time-resolved PIV (Particle Image Velocimetry) is used as a main measurement technique. The flow field behind the profile is captured in longitudinal plane as well as in cross-section planes using 3D PIV. The results based on statistical quantities will be presented in this paper. More, next part will be devoted to the decomposition analysis of the flow dynamics (BOD, OPD). Pracoviště Ústav termomechaniky Kontakt Marie Kajprová, kajprova@it.cas.cz, Tel.: 266 053 154 ; Jana Lahovská, jaja@it.cas.cz, Tel.: 266 053 823 Rok sběru 2018
Počet záznamů: 1