- Complex interferometry principles and its potential in case of refere…
Počet záznamů: 1  

Complex interferometry principles and its potential in case of reference interferograms availability

  1. 1.
    SYSNO ASEP0473373
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevComplex interferometry principles and its potential in case of reference interferograms availability
    Tvůrce(i) Kálal, M. (CZ)
    Křupka, M. (CZ)
    Dostál, Jan (UFP-V) RID, ORCID
    Dudžák, Roman (UFP-V) RID, ORCID
    Ullschmied, Jiří (UFP-V) RID
    Číslo článku118792
    Zdroj.dok.Proceedings of Science: 1st EPS Conference on Plasma Diagnostics, ECPD 2015. - Frascati : Proceedings of Science (PoS), 2015 - ISSN 1824-8039
    Poč.str.8 s.
    Forma vydáníTištěná - P
    AkceEPS Conference on Plasma Diagnostics, ECPD 2015/1./
    Datum konání14.04.2015 - 17.04.2015
    Místo konáníFrascati
    ZeměIT - Itálie
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.IT - Itálie
    Klíč. slovaEngineering controlled terms ; Laser diagnostics ; Laser produced plasmas ; Plasma diagnostics
    Vědní obor RIVBH - Optika, masery a lasery
    CEPLM2010014 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GPP205/11/P712 GA ČR - Grantová agentura ČR
    Institucionální podporaUFP-V - RVO:61389021
    EID SCOPUS84959036363
    AnotaceClassical interferometry is one of the key methods in laser-produced plasma diagnostics. Its more advanced version, which allows recording and subsequent reconstruction of up to three sets of data using just one data object-A complex interferogram-was developed in the past and became known as complex interferometry. Employing this diagnostics, not only the usual phase shift, but also the amplitude of the probing beam as well as the fringe contrast (leading directly to the phase shift time derivative) can be reconstructed simultaneously from such a complex interferogram. In this paper it will be demonstrated that even in the case of a not particularly good diagnostic beam quality these three quantities can be reconstructed with a high degree of accuracy provided both the diagnostic beam as well as the corresponding optical line feature a reasonable stability. Such stability requirement is important as all together four shots need to be recorded: the signal complex interferogram, the reference interferogram as well as the intensity structures of the signal and reference part of the diagnostic beam.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2017
Počet záznamů: 1  

Metadata v repozitáři ASEP jsou licencována pod licencí CC0.

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.