Počet záznamů: 1
Soft X-ray tomography in support of impurity control in tokamaks
- 1.
SYSNO ASEP 0466026 Druh ASEP C - Konferenční příspěvek (mezinárodní konf.) Zařazení RIV D - Článek ve sborníku Název Soft X-ray tomography in support of impurity control in tokamaks Tvůrce(i) Mlynář, Jan (UFP-V) RID
Mazon, D. (FR)
Imríšek, Martin (UFP-V) RID
Löffelmann, Viktor (UFP-V)
Malard, P. (FR)
Odstrčil, T. (DE)
Tomeš, Matěj (UFP-V)
Vezinet, V. (DE)
Weinzettl, Vladimír (UFP-V) RID, ORCIDČíslo článku 012001 Zdroj.dok. Journal of Physics: Conference Series, 768. - Bristol : IOP Publishing, Ltd., 2016 - ISSN 1742-6588 Poč.str. 10 s. Forma vydání Tištěná - P Akce International Workshop & Summer School on Plasma Physics 2014 (IWSSPP’14)/6./ Datum konání 30.06.2014 - 06.07.2014 Místo konání Kiten Země BG - Bulharsko Typ akce WRD Jazyk dok. eng - angličtina Země vyd. GB - Velká Británie Klíč. slova soft X-ray ; tomography ; tokamak Vědní obor RIV BL - Fyzika plazmatu a výboje v plynech Obor OECD Fluids and plasma physics (including surface physics) CEP GAP205/10/2055 GA ČR - Grantová agentura ČR LG14002 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LM2011021 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Institucionální podpora UFP-V - RVO:61389021 UT WOS 000439544000001 EID SCOPUS 84996928511 DOI 10.1088/1742-6596/768/1/012001 Anotace This contribution reviews an important example of current developments in diagnostic systems and data analysis tools aimed at improved understanding and control of transport processes in magnetically confined high temperature plasmas. The choice of tungsten
for the plasma facing components of ITER and probably also DEMO means that impurity control in fusion plasmas is now a crucial challenge. Soft X-ray (SXR) diagnostic systems serve as a key sensor for experimental studies of plasma impurity transport with a clear
prospective of its control via actuators based mainly on plasma heating systems. The SXR diagnostic systems typically feature high temporal resolution but limited spatial resolution due to access restrictions. In order to reconstruct the spatial distribution of the SXR radiation from line integrated measurements, appropriate tomographic methods have been developed and validated, while novel numerical methods relevant for real-time control have been proposed. Furthermore, in order to identify the main contributors to the SXR plasma radiation, at least partial control over the spectral sensitivity range of the detectors would be beneficial, which motivates for developments of novel SXR diagnostic methodsPracoviště Ústav fyziky plazmatu Kontakt Vladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975 Rok sběru 2017
Počet záznamů: 1