Quantitative Raman Spectroscopy Analysis of Polyhydroxyalkanoates Produced by Cupriavidus necator H16

  1. 1.
    SYSNO ASEP0464550
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevQuantitative Raman Spectroscopy Analysis of Polyhydroxyalkanoates Produced by Cupriavidus necator H16
    Tvůrce(i) Samek, Ota (UPT-D) RID, ORCID, SAI
    Obruča, S. (CZ)
    Šiler, Martin (UPT-D) RID, ORCID, SAI
    Sedláček, P. (CZ)
    Benešová, P. (CZ)
    Kučera, D. (CZ)
    Márová, I. (CZ)
    Ježek, Jan (UPT-D) RID, ORCID, SAI
    Bernatová, Silvie (UPT-D) RID, SAI
    Zemánek, Pavel (UPT-D) RID, SAI, ORCID
    Celkový počet autorů10
    Zdroj.dok.Sensors. - : MDPI
    Roč. 16, č. 11 (2016), 1808:1-7
    Poč.str.7 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaRaman spectroscopy ; Cupriavidus necator H16 ; polyhydroxyalkanoates
    Vědní obor RIVBH - Optika, masery a lasery
    CEPGA15-20645S GA ČR - Grantová agentura ČR
    LO1212 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    ED0017/01/01 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUPT-D - RVO:68081731
    UT WOS000389641700041
    EID SCOPUS84994791887
    DOI10.3390/s16111808
    AnotaceWe report herein on the application of Raman spectroscopy to the rapid quantitative analysis of polyhydroxyalkanoates (PHAs), biodegradable polyesters accumulated by various bacteria. This theme was exemplified for quantitative detection of the most common member of PHAs, poly(3-hydroxybutyrate) (PHB) in Cupriavidus necator H16. We have identified the relevant spectral region (800–1800 cm(−1)) incorporating the Raman emission lines exploited for the calibration of PHB (PHB line at 1736 cm(−1)) and for the selection of the two internal standards (DNA at 786 cm(−1)) and Amide I at 1662 cm(−1)). In order to obtain quantitative data for calibration of intracellular content of PHB in bacterial cells reference samples containing PHB amounts—determined by gas chromatography—from 12 percent to 90 percent (w/w) were used. Consequently, analytical results based on this calibration can be used for fast and reliable determination of intracellular PHB content during biotechnological production of PHB since the whole procedure—from bacteria sampling, centrifugation, and sample preparation to Raman analysis—can take about 12 min. In contrast, gas chromatography analysis takes approximately 8 h.
    PracovištěÚstav přístrojové techniky