- Note: Precise phase and frequency comparator based on direct phase-ti…
Počet záznamů: 1  

Note: Precise phase and frequency comparator based on direct phase-time measurements

  1. 1.
    SYSNO ASEP0441135
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevNote: Precise phase and frequency comparator based on direct phase-time measurements
    Tvůrce(i) Prochazka, I. (CZ)
    Pánek, Petr (URE-Y) RID
    Kodet, J. (CZ)
    Celkový počet autorů3
    Zdroj.dok.Review of Scientific Instruments. - : AIP Publishing - ISSN 0034-6748
    Roč. 85, č. 12 (2014), s. 126110
    Poč.str.3 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaClocks ; Oscillators ; Stability
    Vědní obor RIVJA - Elektronika a optoelektronika, elektrotechnika
    Institucionální podporaURE-Y - RVO:67985882
    UT WOS000347168500083
    EID SCOPUS84919772395
    DOI https://doi.org/10.1063/1.4904735
    AnotaceWe are reporting on the design, performance, and application results of a phase and frequency comparator based on the direct phase-time measurement using a high performance event timer. The advantages of this approach are the simple implementation, a broad frequency range, and the clear interpretation of the measured results. Primarily we analyzed the background instability of the instrument in a common-clock test when a 200 MHz clock signal was connected to both inputs and the noise bandwidth was kept at 5 Hz by a preprocessing of the measured data. The results show that the Allan deviation of the background instability follows 4 x 10(-14)/tau for a wide range of averaging intervals from 0.1 s up to 10(4) s. These results are better than background instability of commercially available state-of-the-art instruments based on the phase difference multiplication. Finally the instrument was used for comparison of two H-masers. This experiment proofed that one of possible applications is a comparison of low-noise highly stable frequency sources and measurement of their frequency stability in the time-domain. The noise background of the instrument was negligible for averaging intervals longer than 100 ms
    PracovištěÚstav fotoniky a elektroniky
    KontaktPetr Vacek, vacek@ufe.cz, Tel.: 266 773 413, 266 773 438, 266 773 488
    Rok sběru2015
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.