Počet záznamů: 1  

Validation of Flotac for the detection and quantification of Troglodytella abrassarti and Neobalantidium coli in chimpanzees and pigs

  1. 1.
    SYSNO ASEP0434089
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevValidation of Flotac for the detection and quantification of Troglodytella abrassarti and Neobalantidium coli in chimpanzees and pigs
    Tvůrce(i) Růžicová, M. (CZ)
    Petrželková, Klára Judita (UBO-W) RID, SAI, ORCID
    Kalousová, B. (CZ)
    Modrý, D. (CZ)
    Pomajbíková, K. (CZ)
    Celkový počet autorů5
    Zdroj.dok.Journal of Parasitology. - : Allen Press - ISSN 0022-3395
    Roč. 100, č. 5 (2014), s. 662-670
    Poč.str.9 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaciliates ; chimpanzees ; pigs
    Vědní obor RIVEG - Zoologie
    CEPGA206/09/0927 GA ČR - Grantová agentura ČR
    Institucionální podporaUBO-W - RVO:68081766
    UT WOS000344159300015
    EID SCOPUS84908302095
    DOI https://doi.org/10.1645/14-505.1
    AnotaceWe carried out a calibration of FLOTAC for ciliates Troglodytella abrassarti and Neobalantidium coli based on the selection of a most appropriate flotation solutions, and we also tested its accuracy (i.e., number of detected stages out of known added number of stages to fecal samples) and sensitivity for trophozoites of both ciliates in chimpanzee feces and N. coli cysts in pig feces, compared the detection threshold of FLOTAC with MIF-based sedimentation, and, subsequently, tested the losses of ciliate stages during sample preparation. Nine flotation solutions were evaluated, and ZnSO4 solution (specific gravity [s.g.] 1.2) showed to be the most suitable for trophozoite detection, while Sheather's solution (s.g. 1.33) was selected as most suitable for cysts. The FLOTAC sensitivity in detection of both stages varied: for trophozoites, we found all samples were positive when the intensity of infection 10 trophozoites per gram and higher, whereas for cysts the sensitivity was lower. The accuracy of FLOTAC negatively correlated with infection intensity, and the merthiolate-iodine-formaldehyde sedimentation-based quantification had a lower detection threshold. We demonstrated additional losses of stages of T. abrassarti and N. coli due to their retention in the sediment, which is probably a major reason for discrepancies in the numbers of countable ciliates between both methods. In conclusion, the FLOTAC should not be considered as a gold standard for quantification of intestinal ciliates in primates; instead, we recommend the modified MIF method.
    PracovištěÚstav biologie obratlovců
    KontaktHana Slabáková, slabakova@ivb.cz, Tel.: 543 422 524
    Rok sběru2015
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.