Počet záznamů: 1  

Hydrogen-terminated diamond sensors for electrical monitoring of cells

  1. 1.
    SYSNO ASEP0432182
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevHydrogen-terminated diamond sensors for electrical monitoring of cells
    Tvůrce(i) Ižák, Tibor (FZU-D) RID
    Novotná, Katarína (FGU-C)
    Kopová, Ivana (FGU-C) RID
    Bačáková, Lucie (FGU-C) RID, ORCID
    Varga, Marián (FZU-D) RID, ORCID
    Rezek, Bohuslav (FZU-D) RID, ORCID
    Kromka, Alexander (FZU-D) RID, ORCID, SAI
    Zdroj.dok.Key Engineering Materials : Materials and Applications for Sensors and Transducers III, 605. - Zurich : Trans Tech Publications, 2014 / Hristoforou E. ; Vlachos D.S. - ISSN 1013-9826 - ISBN 9783038350514
    Rozsah strans. 577-580
    Poč.str.4 s.
    Forma vydáníTištěná - P
    AkceInternational Conference on Materials and Applications for Sensors and Transducers /3./ (IC-MAST 2013)
    Datum konání13.09.2013-17.09.2013
    Místo konáníPraha
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovadiamond thin films ; label-free biosensors ; real-time monitoring ; cell cultivation ; impedance measurements
    Vědní obor RIVJB - Senzory, čidla, měření a regulace
    CEPGAP108/11/0794 GA ČR - Grantová agentura ČR
    Institucionální podporaFZU-D - RVO:68378271 ; FGU-C - RVO:67985823
    UT WOS000348035600142
    EID SCOPUS84900442985
    DOI10.4028/www.scientific.net/KEM.605.577
    AnotaceIn this paper we introduce fully optically transparent impedance biosensors based on intrinsic nanocrystalline diamond (NCD) films deposited on glass substrate. Prepared sensors have an interdigital electrode (IDE) structures realized by local hydrogen and oxygen termination of diamond surface, which mean in-plane configuration of active sensor area. Sensors were tested by real time monitoring of human osteoblast-like MG 63 cells in wide frequency range from 10 Hz to 100 kHz for several days. Two different measurement setups were used and compared regarding to their advantages and disadvantages. Proof of concept of diamond-based impedance sensor is showed, i.e. time dependence and frequency dependence (Nyquist plots) of absolute impedance.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2015
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.