    Behaviour of concrete in tunels and undeground concstructions in case of fire.
    5th International Colloquium on Geomechanics and Geophysics. GECO 2014. Vol. 5. Ostrava: Ústav geoniky AV ČR, 2014 - (Koníček, P.; Souček, K.; Heroldová, N.). s. 85-86. ISBN 978-80-86407-49-4.
    [5th International Colloquium on Geomechanics and Geophysics. 24.06.2014-27.06.2014, Ostravice, Karolínka]
    Grant CEP: GA ČR GAP104/12/1988
    Institucionální podpora: RVO:68145535
    Klíčová slova: tunnel * concrete * high temperature * fire
    Kód oboru RIV: JM - Inženýrské stavitelství

    The problem of cement concrete resistance to high temperatures became topical after more frequent car accidents, heavy good vehicles in particular, in tunnels with an outbreak of fire as a result of an accident. Tunnel lining is exposed to intensive temperature released as a result of fire with the temperatures high above 1000 ˚C. The inner part of lining is exposed to various temperature intensities depending on the distance from the fire. Owing to water steam expansion in concrete as a result of temperature-time exposure, concrete surface is cracking and concrete layers are peeled off from various depths and thus the lining is secondary damaged. Appropriate composition of concrete, selection of binder of cement composite material and selection aggregate, additions and/or adding dispersed polypropylene fiber reinforcement can reduce destructive action of high temperature.
    Trvalý link: http://hdl.handle.net/11104/0235219

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    UGN_0430266.pdf1386.9 KBVydavatelský postprintpovolen
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.