Počet záznamů: 1  

Laser system for high resolution Thomson scattering diagnostics on the COMPASS tokamak

  1. 1.
    SYSNO ASEP0349432
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevLaser system for high resolution Thomson scattering diagnostics on the COMPASS tokamak
    Tvůrce(i) Böhm, Petr (UFP-V) RID
    Šesták, David (UFP-V) RID
    Bílková, Petra (UFP-V) RID
    Aftanas, Milan (UFP-V) RID
    Weinzettl, Vladimír (UFP-V) RID, ORCID
    Hron, Martin (UFP-V) RID, ORCID
    Pánek, Radomír (UFP-V) RID
    Baillon, L. (FR)
    Dunstan, M.R. (GB)
    Naylor, G. (GB)
    Walsh, M.J. (FR)
    Zdroj.dok.Review of Scientific Instruments. - : AIP Publishing - ISSN 0034-6748
    Roč. 81, č. 10 (2010), 10D511-10D511
    Poč.str.4 s.
    Forma vydáníweb - web
    AkceTOPICAL CONFERENCE ON HIGH-TEMPERATURE PLASMA DIAGNOSTICS/18th./
    Datum konání16.05.2010-20.05.2010
    Místo konáníWildwood, New Jersey
    ZeměUS - Spojené státy americké
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaplasma boundary layers ; plasma diagnostics ; Tokamak devices
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    CEPGA202/09/1467 GA ČR - Grantová agentura ČR
    GD202/08/H057 GA ČR - Grantová agentura ČR
    7G09042 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    CEZAV0Z20430508 - UFP-V (2005-2011)
    UT WOS000283754000049
    DOI10.1063/1.3460450
    AnotaceA new Thomson scattering diagnostic has been designed and is currently being installed on the COMPASS tokamak in IPP Prague in the Czech Republic. The requirements for this system are very stringent with approximately 3 mm spatial resolution at the plasma edge. A critical part of this diagnostic is the laser source. To achieve the specified parameters, a multilaser solution is utilized. Two 30 Hz 1.5 J Nd:YAG laser systems, used at the fundamental wavelength of 1064 nm, are located outside the tokamak area at a distance of 20 m from the tokamak. The design of the laser beam transport path is presented. The approach leading to a final choice of optimal focusing optics is given. As well as the beam path to the tokamak, a test path of the same optical length was built. Performance tests of the laser system carried out using the test path are described.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2011
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.