Počet záznamů: 1
The comparison of impedance-based method of cell proliferation monitoring with commonly used metabolic-based techniques
- 1.0340579 - BFÚ 2010 RIV SE eng J - Článek v odborném periodiku
Vištejnová, L. - Dvořáková, J. - Hašová, M. - Muthny, T. - Velebný, V. - Souček, Karel - Kubala, Lukáš
The comparison of impedance-based method of cell proliferation monitoring with commonly used metabolic-based techniques.
Neuroendocrinology Letters. Roč. 30, č. 1 (2009), s. 121-127. ISSN 0172-780X. E-ISSN 2354-4716
Grant CEP: GA MŠMT(CZ) OC08058; GA ČR(CZ) GA524/08/1753
Výzkumný záměr: CEZ:AV0Z50040507; CEZ:AV0Z50040702
Klíčová slova: fibroblasts * keratinocytes * viability
Kód oboru RIV: BO - Biofyzika
Impakt faktor: 1.047, rok: 2009
The study shows the impedance-based detection of viable adherent cells is a valuable approach for cytokinetics and pharmacological studies. However, the specific morphological characteristics of cell lines have to be considered employing this method for determination of cell proliferation without using other reference methods.
Trvalý link: http://hdl.handle.net/11104/0183791