Název | Friction factors for flow of drag reducing solutions of micellar surfactant additives in straight circular pipes and conventional globe valves
|
---|
Překlad názvu | Součinitelé tření při proudění roztoků micelárních surfaktantů snižujících tření přímými kruhovými trubkami a sedlovými ventily
|
---|
Tvůrce(i) | Dostál, M. (CZ) Šesták, J. (CZ) Mík, Václav (UH-J) Myška, Jiří (UH-J) Toman, Jiří (UH-J)
|
---|
Zdroj.dok. | 15. International Congress on Rheology. - Melville,New York : American Institute of Physics, 2008 / Co Albert ; Colby Ralph H. ; Leal Gary L. ; Giacomin Jeffrey A.
- ISSN 0094-243X
- ISBN 978-0-7354-0549-3
|
---|
Rozsah stran | s. 132-134
|
---|
Poč.str. | 3 s.
|
---|
Akce | International Congress On Rheology /15./
|
---|
Datum konání | 03.08.2008-08.08.2008
|
---|
Místo konání | Monterey
|
---|
Země | US - Spojené státy americké
|
---|
Typ akce | WRD
|
---|
Jazyk dok. | eng - angličtina
|
---|
Země vyd. | US - Spojené státy americké
|
---|
Klíč. slova | Drag reduction ; surfactants ; fiction factor
|
---|
Vědní obor RIV | EE - Mikrobiologie, virologie
|
---|
CEP | GA101/06/1478 GA ČR - Grantová agentura ČR
|
---|
CEZ | AV0Z20600510 - UH-J (2005-2011)
|
---|
UT WOS | 000257623000044
|
---|
Anotace | Experiments were carried out in order to investigate pressure drops due to friction and form for flow of water with micellar drag reducing additives Arquad S-50, CTAB and CTAC, which were prepared in various different concentrations. The rheological behavior of these solutions was studied on a coaxial cylinder rheometer. Standard experimental data evaluation in the form of flow curves disclosed a pattern in which, in the low shear rate range, a nonlinear shear stress decrease with increasing shear rates was observed. For still higher shear rates, shear stress values approached asymptotically constant, shear-independent, values. Therefore, in the low shear rate region, experimental data were described with sufficient accuracy by means of the simple power-law model. A closed-loop experimental stand consisted of a 2700 mm long stabilization section followed either by a 3000 mm long straight, stainless circular tube, (15, 20, and 25 mm I.D.) or with a conventional globe valve.
|
---|