Design of Compact Vacuum Setup for Al+ and Ca+ Ion Trapping with Homogeneous Magnetic Field

  1. 1.
    SYSNO ASEP0580577
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevDesign of Compact Vacuum Setup for Al+ and Ca+ Ion Trapping with Homogeneous Magnetic Field
    Tvůrce(i) Grim, Jakub (UPT-D)
    Vlček, Ivan (UPT-D) RID, ORCID, SAI
    Jedlička, Petr (UPT-D) RID, SAI
    Pham, Minh Tuan (UPT-D) RID, ORCID, SAI
    Řeřucha, Šimon (UPT-D) RID, ORCID, SAI
    Čížek, Martin (UPT-D) RID, ORCID, SAI
    Kovalenko, A. (CZ)
    Slodička, L. (CZ)
    Číp, Ondřej (UPT-D) RID, SAI, ORCID
    Celkový počet autorů0
    Zdroj.dok.2023 Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS). Proceedings. - New York : IEEE, 2023 - ISBN 979-8-3503-1142-6
    Rozsah stran(2023)
    Poč.str.4 s.
    Forma vydáníOnline - E
    Akce2023 Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)
    Datum konání15.05.2023 - 19.05.2023
    Místo konáníToyama
    ZeměJP - Japonsko
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaIon trap ; vacuum chamber ; homogeneous magnetic field ; calcium ions ; aluminium ions
    Vědní obor RIVBH - Optika, masery a lasery
    Obor OECDOptics (including laser optics and quantum optics)
    CEPEF16_026/0008460 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUPT-D - RVO:68081731
    EID SCOPUS85175336476
    DOI10.1109/EFTF/IFCS57587.2023.10272116
    AnotaceWe present our arrangement of new apparatus for trapping Ca+ and Al+ ions. The apparatus consists of a compact vacuum chamber, linear quadrupole trap, one pair of Helmholtz coils, two pairs of saddle coils, and a magnetic shield. The new design respects the requirement of the large optical access for laser beam integration, a homogeneous magnetic field in the position of the ion in the trapping area, and an ultra-high vacuum regime to avoid interactions between residual gas and ions. The new apparatus is designed in a way so that all important subparts can be changed easily and allow us to minimize the time when the inner parts are exposed to the air during a component exchange. All parts of the arrangement, including the quadrupole trap, have been designed and developed by the Institute of Scientific Instruments in Brno, Czech Republic.