Počet záznamů: 1  

A simple electroanalysis of polyG RNA in mixtures with 3',5'-cyclic guanosine monophosphate achieved by selective desorption of the monomers from the electrode surface

  1. 1.
    SYSNO ASEP0554407
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevA simple electroanalysis of polyG RNA in mixtures with 3',5'-cyclic guanosine monophosphate achieved by selective desorption of the monomers from the electrode surface
    Tvůrce(i) Hesko, Ondřej (BFU-R)
    Fojta, Miroslav (BFU-R) RID, ORCID
    Špaček, Jan (BFU-R) ORCID
    Celkový počet autorů3
    Číslo článku115773
    Zdroj.dok.Journal of Electroanalytical Chemistry. - : Elsevier - ISSN 1572-6657
    Roč. 901, NOV 15 2021 (2021)
    Poč.str.6 s.
    Forma vydáníOnline - E
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaelectrochemical oxidation ; nucleic-acids ; oligonucleotides ; dna ; voltammetry
    Vědní obor RIVCG - Elektrochemie
    Obor OECDElectrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
    CEPEF15_003/0000477 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GA20-03187S GA ČR - Grantová agentura ČR
    Způsob publikováníOmezený přístup
    Institucionální podporaBFU-R - RVO:68081707
    UT WOS000714137900001
    EID SCOPUS85117389455
    DOI10.1016/j.jelechem.2021.115773
    AnotacePreviously it has been shown that cyclic nucleoside monophosphates can spontaneously polymerize to form RNA oligonucleotides under conditions simulating prebiotic conditions on Archean Earth. The most efficient polymerization was documented with 3',5'-cyclic guanosine monophosphate (cGMP). In this work a method for fast detection of short polyG RNAs present in a large overabundance of cGMP, modeling conditions in the non-enzymatic nucleotide polymerization mixtures, is presented. The method is based on electrochemical measurements of guanine (G) oxidation signals yielded by RNA oligomers adsorbed onto the surface of a pyrolytic graphite electrode (PGE). To avoid false positive results arising from the G oxidation signals due to coadsorbed cGMP, a method for selective removal of the monomers from the electrode surface has been devised. In the first step, both cGMP and RNAs are co-adsorbed onto the PGE surface. In the second step, the cGMP is selectively desorbed using treatments in solutions of different tested surfactants (SDS, Tween 20 or Triton X100), or by washing in deionized water at elevated temperature. We show that this new approach is suitable for selective analysis of products of polymerization reactions from mixtures of their building blocks.
    PracovištěBiofyzikální ústav
    KontaktJana Poláková, polakova@ibp.cz, Tel.: 541 517 244
    Rok sběru2022
    Elektronická adresahttps://www.sciencedirect.com/science/article/pii/S1572665721007992?via%3Dihub
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.