Počet záznamů: 1  

Electrodeposition of Silver Amalgam on Thin Gold Film Electrodes for Voltammetric Detection of 4-Nitrophenol and DNA Labeled with Osmium Tetroxide-Bipyridine Complex

  1. 1.
    SYSNO ASEP0518368
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevElectrodeposition of Silver Amalgam on Thin Gold Film Electrodes for Voltammetric Detection of 4-Nitrophenol and DNA Labeled with Osmium Tetroxide-Bipyridine Complex
    Tvůrce(i) Havranová-Vidláková, Pavlína (BFU-R) ORCID
    Ligmajer, Filip (BFU-R) ORCID
    Daňhel, Aleš (BFU-R) RID, ORCID
    Celkový počet autorů3
    Zdroj.dok.Electroanalysis. - : Wiley - ISSN 1040-0397
    Roč. 31, č. 10 (2019), s. 1952-1960
    Poč.str.9 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.DE - Německo
    Klíč. slovanucleic-acid ; carbon ; nanoparticles ; electrochemistry
    Vědní obor RIVCG - Elektrochemie
    Obor OECDAnalytical chemistry
    CEPGJ17-23634Y GA ČR - Grantová agentura ČR
    Způsob publikováníOpen access
    Institucionální podporaBFU-R - RVO:68081707
    UT WOS000474183900001
    DOI10.1002/elan.201900306
    AnotaceAlternative electrode materials suitable to prepare novel working electrode applicable in detecting biopolymers such as nucleic acids, proteins or glycoproteins, represent a significant contribution to bio-electroanalysis. Herein, electrodes made of vapor-deposited thin gold films (vAuE) were used as an alternative substrate for the electrodeposition of silver amalgam particles (AgAPs), next to indium tin oxide and pyrolytic graphite, which are already used. The conditions and parameters of double pulse chronoamperometry were optimized for the most-sensitive voltammetric detection of 4-nitrophenol (4-NP). The resulting electrodes were characterized by scanning electron microscope with energy dispersive X-ray spectroscopy. While 4-NP could not be detected by bare nonactivated vAuEs at all, their electrochemical activation offered a limit of detection (LoD) of 25 and 5 mu mol.l(-1) by means of CV and DPV, respectively. AgAP electrodeposited on vAuE, offered 2.5-times lower LoDs 10 mu mol.l(-1) by CV and comparable LoD 5 mu mol.l(-1) by DPV. Advantageously, AgAPs could be repeatedly deposited on and anodically dissolved from the vAuE with a relative standard deviation 13 % of the ten-times repeated DPV signal of 4-NP (100 mu mol.l(-1)). In comparison to vAuE, the vAuE-AgAP offered about 400 mV broader potential window, which allowed detection of single strand DNA fragment labeled by osmium tetroxide-bipyridine complex down to 2 ng.mu l(-1) by means of DPV.
    PracovištěBiofyzikální ústav
    KontaktJana Poláková, polakova@ibp.cz, Tel.: 541 517 244
    Rok sběru2020
    Elektronická adresahttp://dspace.lib.vutbr.cz/xmlui/bitstream/11012/184643/1/2019%20Electroanalsis%20Havranova%20Preprint.pdf
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.