Počet záznamů: 1  

Treatment of surfaces with slow electrons

  1. 1.
    SYSNO ASEP0460200
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevTreatment of surfaces with slow electrons
    Tvůrce(i) Frank, Luděk (UPT-D) RID, SAI, ORCID
    Mikmeková, Eliška (UPT-D) RID
    Celkový počet autorů2
    Zdroj.dok.Proceedings of the 15th International Seminar on Recent Trends in Charged Particle Optics and Surface Physics Instrumentation. - Brno : Institute of Scientific Instruments CAS, 2016 / Mika Filip - ISBN 978-80-87441-17-6
    Rozsah strans. 10-11
    Poč.str.2 s.
    Forma vydáníTištěná - P
    AkceInternational Seminar on Recent Trends in Charged Particle Optics and Surface Physics Instrumentation /15./
    Datum konání29.05.2016 - 03.06.2016
    Místo konáníSkalský dvůr
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovaelectron microscopy ; SEM ; STEM
    Vědní obor RIVJA - Elektronika a optoelektronika, elektrotechnika
    CEPTE01020118 GA TA ČR - Technologická agentura ČR
    LO1212 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    ED0017/01/01 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUPT-D - RVO:68081731
    UT WOS000391254000003
    AnotaceHistorically, the most annoying obstacle to acquiring SEM micrographs, in particular higher magnification micrographs taken with the ambition of resolving the finest observable details, may be said to be carbonaceous contamination “highlighting” the previous field of view with a black rectangle contoured by an even darker frame. This contamination is generated by decomposition of adsorbed hydrocarbon molecules with incident electrons leaving a crosslinked
    layer of carbon atoms as a surface coating. The darker contours come from high surface mobility of hydrocarbon molecules from outside the field. The situation has been improved in recent decades by a lower pressure and dryer vacuum in specimen chambers, but even under ultrahigh vacuum (UHV) conditions the phenomenon occurs due to hydrocarbon molecules deposited on the specimen when loaded. Therefore, only in-situ cleaning with an
    attachment producing an ion beam solves this problem in UHV, while some plasma cleaners have also started appearing in standard-vacuum SEM chambers. The goal of complete removal of hydrocarbons is motivated by the supposed unavoidability of their decomposition with primary electrons. However, we have found hydrocarbon molecules being released, rather than their decomposition, when the energy of the impinging electrons drops beneath 50 eV or so.
    PracovištěÚstav přístrojové techniky
    KontaktMartina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178
    Rok sběru2017
    Elektronická adresahttp://www.trends.isibrno.cz/
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.