Počet záznamů: 1  

Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment

  1. 1.
    SYSNO ASEP0563828
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevLow exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment
    Tvůrce(i) Abed Abud, A. (GB)
    Abi, B. (GB)
    Acciarri, R. (US)
    Filip, Peter (FZU-D) ORCID
    Kvasnička, Jiří (FZU-D) RID, ORCID
    Lokajíček, Miloš (FZU-D) RID, ORCID
    Zálešák, Jaroslav (FZU-D) RID, ORCID
    Zuklín, Josef (FZU-D) ORCID
    Celkový počet autorů1156
    Číslo článku072006
    Zdroj.dok.Physical Review D. - : American Physical Society - ISSN 2470-0010
    Roč. 105, č. 7 (2022)
    Poč.str.32 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaDUNE ; asymmetry: CP ; sensitivity ; lifetime
    Vědní obor RIVBF - Elementární částice a fyzika vys. energií
    Obor OECDParticles and field physics
    Výzkumná infrastrukturaFermilab-CZ II - 90113 - Fyzikální ústav AV ČR, v. v. i.
    Způsob publikováníOpen access
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000809663000001
    EID SCOPUS85130231695
    DOI10.1103/PhysRevD.105.072006
    AnotaceThe Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE’s sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-calendar years (kt-MW-CY), where calendar years include an assumption of 57% accelerator uptime based on past accelerator performance at Fermilab. The analysis includes detailed uncertainties on the flux prediction, the neutrino interaction model, and detector effects. We demonstrate that DUNE will be able to unambiguously resolve the neutrino mass ordering at a 4σ (5σ) level with a 66 (100) kt-MW-CY far detector exposure, and has the ability to make strong statements at significantly shorter exposures depending on the true value of other oscillation parameters, with a median sensitivity of 3σ for almost all true δCP values after only 24 kt-MW-CY.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2023
    Elektronická adresahttps://hdl.handle.net/11104/0335623
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.