VDI Vision - Analysis of Ventricular Electrical Dyssynchrony in Real-Time

  1. 1.
    SYSNO ASEP0555022
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevVDI Vision - Analysis of Ventricular Electrical Dyssynchrony in Real-Time
    Tvůrce(i) Plešinger, Filip (UPT-D) RID, ORCID, SAI
    Viščor, Ivo (UPT-D) RID, ORCID, SAI
    Vondra, Vlastimil (UPT-D) RID, ORCID, SAI
    Halámek, Josef (UPT-D) RID, ORCID, SAI
    Koščová, Zuzana (UPT-D)
    Leinveber, P. (CZ)
    Čurila, K. (CZ)
    Jurák, Pavel (UPT-D) RID, ORCID, SAI
    Celkový počet autorů8
    Číslo článku103
    Zdroj.dok.2021 Computing in Cardiology (CinC), 48. - New York : IEEE, 2021 - ISSN 2325-8861 - ISBN 978-166547916-5
    Poč.str.4 s.
    Forma vydáníOnline - E
    AkceComputing in Cardiology 2021 /48./
    Datum konání12.09.2021 - 15.09.2021
    Místo konáníBrno
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaUltra high frequency ECG ; Ventricular Electrical Dyssynchrony ; real-time analysis
    Vědní obor RIVFS - Lékařská zařízení, přístroje a vybavení
    Obor OECDMedical engineering
    Institucionální podporaUPT-D - RVO:68081731
    EID SCOPUS85124754259
    DOI10.23919/CinC53138.2021.9662916
    AnotaceBackground: Ventricular electrical dyssynchrony can be examined using ultra-high-frequency (UHF-ECG) analysis. Furthermore, UHF-ECG analysis would allow direct optimization of pacing therapy. Here we introduce VDI vision (Ventricular Dyssynchrony Imaging), a desktop application for the real-time processing of UHF-ECG recordings. Method: Incoming ECG data (5kHz, 26 bits, 24 channels) are processed as follows: QRS detection, pacemaker stimuli elimination, QRS clustering, amplitude envelopes in nine frequency bands, and final combination into the Ventricular Depolarization (VD) map. The VD map is updated whenever a new QRS is detected. Results: We developed the VDI vision using the. NET platform. Until the end of March 2021, the VDI monitor was used to analyze 773 and 4,849 recordings at ICRC-FNUSA hospital (Brno, Czechia) and FNKV hospital (Prague, Czechia), respectively. The median length for ICRC-FNUSA recordings was 124 (IQR 121-139) seconds. The median length for recordings at FNKV hospital was 157 seconds (IQR 127-200). Conclusion: The VDI vision delivers information about electrical ventricular dyssynchrony in real-time. The instant analysis allows using the software during implant procedures for optimizing electrode placement and pacing. The presented real-time solution also significantly minimized measurement duration.
    PracovištěÚstav přístrojové techniky
    KontaktMartina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178
    Rok sběru2022
    Elektronická adresahttps://ieeexplore.ieee.org/document/9662916