Počet záznamů: 1
Implant-forming polymeric 19F MRI-tracer with tunable dissolution
- 1.
SYSNO ASEP 0531585 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Implant-forming polymeric 19F MRI-tracer with tunable dissolution Tvůrce(i) Kolouchová, Kristýna (UMCH-V) ORCID, RID
Jirák, D. (CZ)
Groborz, Ondřej (UMCH-V) ORCID, RID
Sedlacek, O. (BE)
Ziolkowska, N. (CZ)
Vít, M. (CZ)
Sticová, E. (CZ)
Gálisová, A. (CZ)
Švec, Pavel (UMCH-V) RID, ORCID
Trousil, Jiří (UMCH-V) RID, ORCID
Hajek, M. (CZ)
Hrubý, Martin (UMCH-V) RID, ORCIDZdroj.dok. Journal of Controlled Release. - : Elsevier - ISSN 0168-3659
Roč. 327, 10 November (2020), s. 50-60Poč.str. 11 s. Jazyk dok. eng - angličtina Země vyd. NL - Nizozemsko Klíč. slova polymer implant ; 19F magnetic resonance imaging ; double-stimuli responsivity Vědní obor RIV CD - Makromolekulární chemie Obor OECD Polymer science CEP LTC19032 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LO1507 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy GA18-07983S GA ČR - Grantová agentura ČR Způsob publikování Omezený přístup Institucionální podpora UMCH-V - RVO:61389013 UT WOS 000585933700006 EID SCOPUS 85089267901 DOI 10.1016/j.jconrel.2020.07.026 Anotace Magnetic resonance imaging (MRI) using 19F-based tracers has emerged as a promising multi-purpose noninvasive diagnostic tool and its application requires the use of various 19F-based tracers for the intended diagnostic purpose. In this study, we report a series of double-stimuli-responsive polymers for use as injectable implants, which were designed to form implants under physiological conditions, and to subsequently dissolve with different dissolution rates (t1/2 ranges from 30 to more than 250 days). Our polymers contain a high concentration of fluorine atoms, providing remarkable signal detectability, and both a hydrophilic monomer and a pH-responsive monomer that alter the biodistribution properties of the implant. The implant location and dissolution were observed using 19F MRI, which allows the anatomic extent of the implant to be monitored. The dissolution kinetics and biocompatibility of these materials were thoroughly analyzed. No sign of toxicity in vitro or in vivo or pathology in vivo was observed, even in chronic administration. The clinical applicability of our polymers was further confirmed via imaging of a rat model by employing an instrument currently used in human medicine. Pracoviště Ústav makromolekulární chemie Kontakt Eva Čechová, cechova@imc.cas.cz ; Tel.: 296 809 358 Rok sběru 2021 Elektronická adresa https://www.sciencedirect.com/science/article/pii/S0168365920304107?via%3Dihub
Počet záznamů: 1