Počet záznamů: 1  

Pixel-wise amplitude distribution evaluation in time average digital holography

  1. 1.
    SYSNO ASEP0499520
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevPixel-wise amplitude distribution evaluation in time average digital holography
    Tvůrce(i) Psota, Pavel (UFP-V) RID, ORCID
    Lédl, Vít (UFP-V) RID
    Matoušek, O. (CZ)
    Doleček, R. (CZ)
    Kredba, J. (CZ)
    Celkový počet autorů5
    Číslo článku012033
    Zdroj.dok.Journal of Physics: Conference Series, Conference 1. - Bristol : IOP Publishing, 2018 - ISSN 1742-6596
    Poč.str.6 s.
    Forma vydáníOnline - E
    Akce13th International Conference on Vibration Measurements by Laser Techniques AIVELA
    Datum konání19.06.2018 - 22.06.2018
    Místo konáníAncona
    ZeměIT - Itálie
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaDigital holography ; Time-average holography ; Scanning holography ; Vibrations ; Phase modulation
    Vědní obor RIVJA - Elektronika a optoelektronika, elektrotechnika
    Obor OECDElectrical and electronic engineering
    CEPGA16-11965S GA ČR - Grantová agentura ČR
    Institucionální podporaUFP-V - RVO:61389021
    DOI10.1088/1742-6596/1149/1/012033
    AnotaceThis article introduces a new holographic method for harmonic vibration measurement. The method called time average sweeping digital holography (TASDH) is based on the continuous shift of fringe pattern described by Bessel function over the object surface. The shift is done by phase modulation in one arm of holographic interferometer. Such temporal phase sweeping allows for evaluation of the vibration amplitude value independently in each pixel by application of intensity values cross-correlation of steady state and oscillating object. Main advantage of proposed technique with respect to other methods of digital holographic vibration is its ability to measure the amplitude of vibration without the risk of interference order mismatch. Thanks to above mentioned properties, the method allows measurement of amplitude modes with high slopes or discontinuous surfaces as well as partially shaded objects. The method was experimentally tested by measuring the bending beam cantilever. The standard deviation of the measured noise is below nanometer.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2019
    Elektronická adresahttp://iopscience.iop.org/article/10.1088/1742-6596/1149/1/012033/pdf
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.