Počet záznamů: 1  

Histology and micro-CT study of diamond-coated metal bone implants in rabbit femurs

  1. 1.
    SYSNO ASEP0496851
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevHistology and micro-CT study of diamond-coated metal bone implants in rabbit femurs
    Tvůrce(i) Potocký, Štěpán (FZU-D) RID, ORCID
    Ižák, Tibor (FZU-D) RID
    Dragounová, Kateřina (FZU-D) ORCID
    Kromka, Alexander (FZU-D) RID, ORCID, SAI
    Rezek, Bohuslav (FZU-D) RID, ORCID
    Mandys, V. (CZ)
    Bartoš, M. (CZ)
    Bačáková, Lucie (FGU-C) RID, ORCID
    Sedmera, David (FGU-C) RID, ORCID, SAI
    Celkový počet autorů9
    Zdroj.dok.Nanocon 2017 : conference proceedings : 9th International Conference on Nanomaterials - Research & Application. - Ostrava : Tanger Ltd., 2018 - ISBN 9788087294819
    Rozsah strans. 573-577
    Poč.str.5 s.
    Forma vydáníOnline - E
    AkceNANOCON 2017. International Conference on Nanomaterials - Research & Application /9./
    Datum konání18.10.2017 - 20.10.2017
    Místo konáníBrno
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovascrew implant ; diamond coating ; osteointegration ; histology
    Vědní obor RIVBO - Biofyzika
    Obor OECDBiophysics
    Vědní obor RIV – spolupráceFyziologický ústav - Biotechnologie a bionika
    CEPNV15-32497A GA MZd - Ministerstvo zdravotnictví
    Institucionální podporaFZU-D - RVO:68378271 ; FGU-C - RVO:67985823
    UT WOS000452823300094
    EID SCOPUS85051922747
    AnotaceA conformal coating of a thin diamond layer on three-dimensional metal bone implants was shown directly on stainless steel and TiAl6V4 cortical screw implant using ultrasonic and composite polymer pretreatment method. The best conformation coverage was achieved in the case of the WO3 interlayer for both stainless steel and TiAl6V4 screws. The process of osteointegration of the screw implants into rabbit femurs is evidenced by the formation of a bone edge via desmogenous ossification around the screws in less than six months after implantation. A detailed evaluation of the tissue reaction around the implanted screws shows good biocompatibility of diamond-coated metal bone implants.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2019
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.