Počet záznamů: 1  

First results on cell irradiation with laser-driven protons on the TARANIS system

  1. 1.
    SYSNO ASEP0420820
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevFirst results on cell irradiation with laser-driven protons on the TARANIS system
    Tvůrce(i) Kar, S. (GB)
    Doria, D. (GB)
    Kakolee, K.F. (GB)
    Prasad, R. (GB)
    Litt, S. (GB)
    Ahmed, H. (GB)
    Nersisyan, G. (GB)
    Lewis, C. (GB)
    Zepf, M. (GB)
    Borghesi, Marco (FZU-D) RID
    Schettino, G. (GB)
    Prise, K.M. (GB)
    Fiorini, F. (GB)
    Kirby, D. (GB)
    Green, S. (GB)
    Jeynes, J.C.G. (GB)
    Merchant, M.J. (IT)
    Kirkby, K.J. (GB)
    Zdroj.dok.2nd ELIMED Workshop and Panel. - Melville : AIP, 2013 / Margarone D. ; Cirrone P. ; Cuttone G. ; Korn G. - ISBN 978-0-7354-1171-5
    Rozsah strans. 87-89
    Poč.str.3 s.
    Forma vydáníTištěná - P
    AkceMEDical and Multidisciplinary Applications at ELI (ELIMED) Workshop and Panel /2./
    Datum konání18.10.2012-19.10.2012
    Místo konáníCatania
    ZeměIT - Itálie
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaTARANIS Terawatt laser ; proton irradiation ; radiobiological studies ; cells
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    CEPED1.1.00/02.0061 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    EE.2.3.20.0087 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000324289100013
    DOI10.1063/1.4816612
    AnotaceThe ultra short duration of laser-driven multi-MeV ion bursts offers the possibility of radiobiological studies at extremely high dose rates. Employing the TARANIS Terawatt laser at Queen’s University, the effect of proton irradiation at MeV-range energies on live cells has been investigated at dose rates exceeding 109 Gy/s as a single exposure. A clonogenic assay showed consistent lethal effects on V-79 live, cells, which, even at these dose rates, appear to be in line with previously published results employing conventional sources. A Relative Biological Effectiveness (RBE) of 1.4±0.2 at 10% survival is estimated from a comparison with a 225 kVp X-ray source.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579