Počet záznamů: 1  

Iodine based reference laser for ground tests of LISA payload

  1. 1.
    SYSNO ASEP0582261
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevIodine based reference laser for ground tests of LISA payload
    Tvůrce(i) Mehlman, A. (FR)
    Holleville, D. (FR)
    Lours, M. (FR)
    Pointard, B. (FR)
    Le Targat, R. (FR)
    Wolf, P. (FR)
    Bize, S. (FR)
    Acef, O. (FR)
    Boutin, A. (FR)
    Lepage, K. (FR)
    Fulop, L. (FR)
    Halloin, H. (FR)
    Zerguerras, T. (FR)
    Hrabina, Jan (UPT-D) RID, ORCID, SAI
    Holá, Miroslava (UPT-D) RID, ORCID, SAI
    Ouda, L. (FR)
    Arguel, R. (FR)
    Celkový počet autorů17
    Číslo článku127777E
    Zdroj.dok.International Conference on Space Optics - ICSO 2022. - Bellingham : SPIE, 2023 / Minoglou K. ; Karafolas N. ; Cugny B. - ISSN 0277-786X - ISBN 9781510668034
    Rozsah stran(2023)
    Poč.str.8 s.
    Forma vydáníTištěná - P
    AkceInternational Conference on Space Optics - ICSO 2022 /14./
    Datum konání03.10.2022 - 07.10.2022
    Místo konáníDubrovnik
    ZeměHR - Chorvatsko
    Typ akceCST
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaDoppler-free spectroscopy ; iodine reference ; LISA ; nonlinear crystals ; PPLN ; Telecom laser ; transportable frequency reference ; ultra-stable laser
    Vědní obor RIVBH - Optika, masery a lasery
    Obor OECDOptics (including laser optics and quantum optics)
    CEPEF16_026/0008460 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUPT-D - RVO:68081731
    EID SCOPUS85174009499
    DOI10.1117/12.2691394
    AnotaceWe report on the development of a transportable iodine frequency stabilized laser setup, based on compact-fibered frequency tripled Telecom laser, locked to the a10 hyperfine component of the 127I2 line at 532.245 nm. Therefore, a tandem of Nd: YAG lasers are phase-locked to this reference laser and used for precise interferometry measurements as part of the French activities in the frame of LISA-France consortium, led by the French space agency (CNES). The frequency stability transfer from 1596 nm to the LISA nominal wavelength at 1064.49 nm is fulfilled in a simple manner [1], using the usual phase locking loop technique associated to a second harmonic generation process. The compact design of the whole setup will make it easily transportable and can be readily used on different sites.
    PracovištěÚstav přístrojové techniky
    KontaktMartina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178
    Rok sběru2024
    Elektronická adresahttps://www.spiedigitallibrary.org/conference-proceedings-of-spie/12777/2691394/Iodine-based-reference-laser-for-ground-tests-of-LISA-payload/10.1117/12.2691394.full#_=_