Air quality in archives housed in historic buildings: Assessment of concentration of indoor particles of outdoor origin.

  1. 1.
    SYSNO ASEP0524772
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevAir quality in archives housed in historic buildings: Assessment of concentration of indoor particles of outdoor origin.
    Tvůrce(i) Mašková, Ludmila (UCHP-M) RID, ORCID, SAI
    Smolík, Jiří (UCHP-M) RID, ORCID, SAI
    Ondráček, Jakub (UCHP-M) RID, ORCID, SAI
    Ondráčková, Lucie (UCHP-M) RID, ORCID, SAI
    Trávníčková, Tereza (UCHP-M) RID, ORCID, SAI
    Havlica, Jaromír (UCHP-M) RID, ORCID, SAI
    Číslo článku107024
    Zdroj.dok.Building and Environment. - : Elsevier - ISSN 0360-1323
    Roč. 180, AUG 2020 (2020)
    Poč.str.10 s.
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovalong-term storage ; naturally ventilated buildings ; mass size distribution
    Vědní obor RIVAL - Umění, architektura, kulturní dědictví
    Obor OECDArts, Art history
    CEPDG18P02OVV048 GA MK - Ministerstvo kultury
    Způsob publikováníOmezený přístup
    UT WOS000562688400013
    EID SCOPUS85085726223
    DOI10.1016/j.buildenv.2020.107024
    AnotaceIndoor air pollution in archives can cause irreversible degradation of materials stored there. Thus, detailed information
    about indoor air quality is essential before control strategies could be investigated. In a period 2008–2019, the relationship between the indoor and outdoor pollution was investigated in four naturally ventilated archives located in historical buildings and situated in regions with different outdoor air quality. The indoor and outdoor particle number, mass, and chemical size distributions were measured during different seasons. Moreover, air change rates (a), penetration coefficients (P), and deposition velocities (Vd) were determined. The results revealed that the most important source of the indoor particulate matter was the outdoor air. The size-resolved data with no indoor sources were evaluated using the steady-state solution of the mass balance equation as the I/O ratio. The results showed that all parameters (a, P, and Vd) determined in archives were comparable with low seasonal variation, probably due to the similar building characteristics. Further, the typical average values of the I/O ratio for naturally ventilated historical buildings were estimated. Finally, the long-term indoor concentrations, for periods when no measurement was in place, were determined using data from the local monitoring network. The results showed that the higher level of pollution and therefore the higher degree of degradation is expected in depositories located in highly polluted regions.