Počet záznamů: 1
Graphene oxide as a radiation sensitive material for XPS dosimetry
- 1.
SYSNO ASEP 0523927 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Graphene oxide as a radiation sensitive material for XPS dosimetry Tvůrce(i) Torrisi, L. (IT)
Silipigni, L. (IT)
Cutroneo, Mariapompea (UJF-V) ORCID, RID, SAI
Torrisi, Alfio (UJF-V) RID, ORCIDCelkový počet autorů 4 Číslo článku 109175 Zdroj.dok. Vacuum. - : Elsevier - ISSN 0042-207X
Roč. 173, č. 3 (2020)Poč.str. 8 s. Forma vydání Tištěná - P Akce 24th Ion Surface Interactions Conference Datum konání 19.08.2019 - 23.08.2019 Místo konání Moscow Země RU - Rusko Typ akce WRD Jazyk dok. eng - angličtina Země vyd. GB - Velká Británie Klíč. slova Graphene oxide ; reduced graphene oxide ; XPS analysis ; dosimeter ; soft X-ray dose Vědní obor RIV BG - Jaderná, atomová a mol. fyzika, urychlovače Obor OECD Materials engineering CEP LM2015056 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy GBP108/12/G108 GA ČR - Grantová agentura ČR Způsob publikování Omezený přístup Institucionální podpora UJF-V - RVO:61389005 UT WOS 000518672200050 EID SCOPUS 85077657199 DOI 10.1016/j.vacuum.2020.109175 Anotace The suitability of graphene oxide (GO) foils as radiation sensitive materials for soft X-ray irradiation is investigated by means of X-ray photoelectron spectroscopy (XPS). In particular GO micrometric foils have been irradiated by soft X-rays at a 1486.6 eV energy at high flux (>10(12) photons/cm(2)s) in ultra-high vacuum. The XPS analysis of the carbon-carbon (CC) and the carbon-oxygen links (CO) characterizes the composition of the first layers of the GO foils. The CC/CO ratio of the high-resolution C1s XPS spectrum is used as dosimetric index. The incident X-ray photons, proportionally to their fluence, partially reduce GO foils decreasing the amount of oxygen groups chemically bonded to carbon network. This decrease causes an increase on the CC/CO ratio that is correlated to the irradiation time, i.e. to the dose absorbed by the GO foil, showing a linear increment with the dose. Our preliminary investigations indicate that GO can be employed to realize a thin foil dosimeter giving a linear response to the absorbed dose in the (275.76 kGy divided by 8.02 MGy) range. The absorbed dose can be also evaluated by measuring the C/O ratio from the C1s and O1s XPS spectra analysis or with different techniques, as discussed in the paper. Pracoviště Ústav jaderné fyziky Kontakt Markéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228 Rok sběru 2021 Elektronická adresa https://doi.org/10.1016/j.vacuum.2020.109175
Počet záznamů: 1