Počet záznamů: 1  

Graphene oxide as a radiation sensitive material for XPS dosimetry

  1. 1.
    SYSNO ASEP0523927
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevGraphene oxide as a radiation sensitive material for XPS dosimetry
    Tvůrce(i) Torrisi, L. (IT)
    Silipigni, L. (IT)
    Cutroneo, Mariapompea (UJF-V) ORCID, RID, SAI
    Torrisi, Alfio (UJF-V) RID, ORCID
    Celkový počet autorů4
    Číslo článku109175
    Zdroj.dok.Vacuum. - : Elsevier - ISSN 0042-207X
    Roč. 173, č. 3 (2020)
    Poč.str.8 s.
    Forma vydáníTištěná - P
    Akce24th Ion Surface Interactions Conference
    Datum konání19.08.2019 - 23.08.2019
    Místo konáníMoscow
    ZeměRU - Rusko
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaGraphene oxide ; reduced graphene oxide ; XPS analysis ; dosimeter ; soft X-ray dose
    Vědní obor RIVBG - Jaderná, atomová a mol. fyzika, urychlovače
    Obor OECDMaterials engineering
    CEPLM2015056 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GBP108/12/G108 GA ČR - Grantová agentura ČR
    Způsob publikováníOmezený přístup
    Institucionální podporaUJF-V - RVO:61389005
    UT WOS000518672200050
    EID SCOPUS85077657199
    DOI10.1016/j.vacuum.2020.109175
    AnotaceThe suitability of graphene oxide (GO) foils as radiation sensitive materials for soft X-ray irradiation is investigated by means of X-ray photoelectron spectroscopy (XPS). In particular GO micrometric foils have been irradiated by soft X-rays at a 1486.6 eV energy at high flux (>10(12) photons/cm(2)s) in ultra-high vacuum. The XPS analysis of the carbon-carbon (CC) and the carbon-oxygen links (CO) characterizes the composition of the first layers of the GO foils. The CC/CO ratio of the high-resolution C1s XPS spectrum is used as dosimetric index. The incident X-ray photons, proportionally to their fluence, partially reduce GO foils decreasing the amount of oxygen groups chemically bonded to carbon network. This decrease causes an increase on the CC/CO ratio that is correlated to the irradiation time, i.e. to the dose absorbed by the GO foil, showing a linear increment with the dose. Our preliminary investigations indicate that GO can be employed to realize a thin foil dosimeter giving a linear response to the absorbed dose in the (275.76 kGy divided by 8.02 MGy) range. The absorbed dose can be also evaluated by measuring the C/O ratio from the C1s and O1s XPS spectra analysis or with different techniques, as discussed in the paper.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2021
    Elektronická adresahttps://doi.org/10.1016/j.vacuum.2020.109175
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.