Počet záznamů: 1  

Rotary swaged laminated Cu-Al composites: Effect of structure on residual stress and mechanical and electric properties

  1. 1.
    0506425 - ÚFM 2020 RIV CH eng J - Článek v odborném periodiku
    Kunčická, Lenka - Kocich, R. - Dvořák, K. - Macháčková, A.
    Rotary swaged laminated Cu-Al composites: Effect of structure on residual stress and mechanical and electric properties.
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING. Roč. 742, JAN (2019), s. 743-750. ISSN 0921-5093
    Grant CEP: GA MŠMT LM2015069
    Institucionální podpora: RVO:68081723
    Klíčová slova: Composites * Neutron diffraction * Electron microscopy * Rotary swaging
    Obor OECD: Materials engineering
    Způsob publikování: Omezený přístup
    https://www.sciencedirect.com/science/article/pii/S0921509318315430?via%3Dihub

    This study focuses on the investigation of uniquely sequenced Cu-Al clad composite wires, which are considered as perspective materials for applications within a wide range of industrial and commercial branches. The wires were produced by rotary swaging under variable temperature (at 20 degrees C and 250 degrees C). The required diameter of the final wire was 5 mm, however, detailed analyses were performed on 10 mm, 7.5 mm, 6 mm and 5 mm samples. The swaged composite wires were studied from the viewpoints of deformation behaviour, structure and mutual interfaces, and electric and mechanical properties via scanning and transmission electron microscopy and neutron diffraction, testing of electrical resistivity, and mechanical testing with implemented acoustic emission detection. The results showed non-negligible effects of both the variables/influencing factors (swaging degree and temperature) on the investigated parameters. The development of intermetallics was observed at the interfaces of samples swaged with high swaging degrees, but only at 250 degrees C. These intermetallics provoked signal activity during acoustic emission detection and deteriorated the electric conductivity. On the other hand, substantial work hardening occurring during swaging at 20 degrees C also decreased the conductivity. By these reasons, the electric properties were the poorest for work hardened samples with occurring intermetallics. Both the final 5 mm composites exhibited satisfactory bonding of both the components and recrystallized structures with ultra-fine grains ensuring the ultimate tensile strength higher than 200 MPa.
    Trvalý link: http://hdl.handle.net/11104/0297727

     
     
Počet záznamů: 1  