Počet záznamů: 1  

System for time-resolved laser absorption spectroscopy and its application to high-power impulse magnetron sputtering

  1. 1.
    SYSNO ASEP0473840
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevSystem for time-resolved laser absorption spectroscopy and its application to high-power impulse magnetron sputtering
    Tvůrce(i) Adámek, Petr (FZU-D) RID, ORCID
    Olejníček, Jiří (FZU-D) RID, ORCID
    Hubička, Zdeněk (FZU-D) RID, ORCID, SAI
    Čada, Martin (FZU-D) RID, ORCID, SAI
    Kment, Štěpán (FZU-D) RID, ORCID
    Kohout, Michal (FZU-D) RID, ORCID
    Do, H.T. (VN)
    Celkový počet autorů7
    Číslo článku023105
    Zdroj.dok.Review of Scientific Instruments. - : AIP Publishing - ISSN 0034-6748
    Roč. 88, č. 2 (2017), s. 1-8
    Poč.str.8 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaplasma diagnostics ; HiPIMS ; time resolved measurement ; laser absorption spectroscopy
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Obor OECDFluids and plasma physics (including surface physics)
    CEPTF01000084 GA TA ČR - Technologická agentura ČR
    GA15-00863S GA ČR - Grantová agentura ČR
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000395902700005
    EID SCOPUS85012005007
    DOI10.1063/1.4975175
    AnotaceThis paper deals with the development and construction of an apparatus for time-resolved tunable diode laser absorption spectroscopy (LAS) for the diagnostics of pulsed plasma. A detailed description of the extension of a progressive method of laser absorption spectroscopy in continuous regime to a direct triggering method of the time-resolved laser absorption spectroscopy (TR-LAS) is presented. The main advantage of the developed method is its capability to measure the time evolution of the whole absorption profile with a preset time resolution, which can be less than 1 mu s. Therefore, the presented method of repetitive sampling applied on LAS in plasma processes is capable of simultaneous measurement of the density and kinetic temperature of selected particles. Its appropriate applications are to periodical processes in technological plasma, namely pulsed plasma discharges. The developed method of TR-LAS was applied to measurements of the temporal evolution of density and kinetic temperature of argon metastable species during high-power impulse magnetron sputtering of titanium and titanium dioxide thin films. .
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2018
Počet záznamů: 1  