- A novel nanospray liquid junction interface for versatile CE-MS
Počet záznamů: 1  

A novel nanospray liquid junction interface for versatile CE-MS

  1. 1.
    SYSNO ASEP0467686
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevA novel nanospray liquid junction interface for versatile CE-MS
    Tvůrce(i) Křenková, Jana (UIACH-O) RID, ORCID
    Haselberg, R. (NL)
    Somsen, G. W. (NL)
    Foret, František (UIACH-O) RID, ORCID
    Celkový počet autorů4
    Zdroj.dok.CECE 2016. 13th International Interdisciplinary Meeting on Bioanalysis. - Brno : Ústav analytické chemie AV ČR, v. v. i., 2016 / Foret František ; Křenková Jana ; Drobníková Iveta ; Klepárník Karel - ISBN 978-80-904959-4-4
    Rozsah strans. 28-28
    Poč.str.1 s.
    Forma vydáníOnline - E
    AkceCECE 2016. International Interdisciplinary Meeting on Bioanalysis /13./
    Datum konání17.10.2016 - 19.10.2016
    Místo konáníBrno
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovacapillary electrophoresis ; mass spectrometry ; liquid junction interface
    Vědní obor RIVCB - Analytická chemie, separace
    CEPGBP206/12/G014 GA ČR - Grantová agentura ČR
    GJ16-09283Y GA ČR - Grantová agentura ČR
    Institucionální podporaUIACH-O - RVO:68081715
    AnotaceIn this work we present a new polyimide-based liquid junction nanospray interface, combining the advantages of sheath flow and sheathless designs. The liquid junction interface was prepared as a hybrid microfabricated plastic liquid junction sprayer allowing to perform analysis in standard (30-100 micro m ID) separation capillaries. The interface incorporates a self-aligning port for coupling of the separation capillary as well as ports for automated flushing of both the liquid junction and the separation capillary. The interface permits performing CE both with and without electroosmotic flow. The use of large bore capillaries allows injection and preconcentration of larger sample volumes, favoring detection sensitivity. Different compositions of the spray liquid and BGE can be used when needed.
    PracovištěÚstav analytické chemie
    KontaktIveta Drobníková, drobnikova@iach.cz, Tel.: 532 290 234
    Rok sběru2017
Počet záznamů: 1  

Metadata v repozitáři ASEP jsou licencována pod licencí CC0.

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.