- Ultra-low-energy STEM in SEM
Počet záznamů: 1  

Ultra-low-energy STEM in SEM

  1. 1.
    SYSNO ASEP0434106
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevUltra-low-energy STEM in SEM
    Tvůrce(i) Frank, Luděk (UPT-D) RID, SAI, ORCID
    Nebesářová, J. (CZ)
    Müllerová, Ilona (UPT-D) RID, SAI, ORCID
    Celkový počet autorů3
    Zdroj.dok.18th International Microscopy Congres. Proceedings. - Praha : Czechoslovak Microscopy Society, 2014 - ISBN 978-80-260-6720-7
    Poč.str.2 s.
    Forma vydáníOnline - E
    AkceInternational Microscopy Congres /18./
    Datum konání07.09.2014-12.09.2014
    Místo konáníPraha
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovatissue section ; biological STEM ; low energy STEM ; low energy electrons
    Vědní obor RIVJA - Elektronika a optoelektronika, elektrotechnika
    CEPTE01020118 GA TA ČR - Technologická agentura ČR
    Institucionální podporaUPT-D - RVO:68081731
    AnotaceExamination of thin samples in TEM or STEM has been performed at hundreds of keV. This energy range offered high resolution but low contrasts which meant that tissue sections had to be contrasted with heavy metal salts. Recent TEM with aberration correctors preserve an acceptable resolution down to 20 keV and provide enhanced contrasts. The LVTEM device is operated at 5 keV on samples thinner than 20 nm. STEM attachments to SEMs have become widespread [3] profiting from an image contrast substantially increasing even for light elements at tens or units of keV. The methods for the preparation of ultrathin sections of various substances are capable of producing layers at and even below 10 nm which enables one to further decrease the energy of the electrons provided the image resolution is maintained. When using the STEM technique virtually all transmitted electrons can be utilised for imaging, while in TEM we are restricted to using electrons capable of forming the final image at acceptable quality. This forces us to narrow the ranges of the angular and energy spreads of electrons that enter the image-forming lenses. Consequently, the STEM technique promises higher contrasts at comparable resolutions. Unlimited reduction of the energy of the illuminating electrons is possible by employing the cathode lens principle. This consists of biasing the sample together with its holder (made flat on both sides) to a high negative potential that retards the incident electrons before they land on the sample surface and accelerates backscattered and transmitted electrons to their respective detectors above and below the sample. Calculations have shown a final spot size only moderately extended even at units of eV so that quality-consistent micrographs can be recorded over the full energy scale.
    PracovištěÚstav přístrojové techniky
    KontaktMartina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178
    Rok sběru2015
Počet záznamů: 1  

Metadata v repozitáři ASEP jsou licencována pod licencí CC0.

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.