Physical simulation of the random failure of implanted braided NiTi stents

  1. 1.
    SYSNO ASEP0432500
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevPhysical simulation of the random failure of implanted braided NiTi stents
    Tvůrce(i) Hiřmanová, Klára (FZU-D)
    Pilch, Jan (FZU-D) RID
    Racek, Jan (FZU-D) RID, ORCID
    Heller, Luděk (FZU-D) RID, ORCID
    Šittner, Petr (FZU-D) RID, ORCID
    Recman, L. (CZ)
    Petrenec, M. (CZ)
    Sedlák, Petr (UT-L) RID, ORCID
    Zdroj.dok.Journal of Materials Engineering and Performance. - : Springer - ISSN 1059-9495
    Roč. 23, č. 7 (2014), s. 2650-2658
    Poč.str.9 s.
    AkceInternational Conference on Shape Memory and Superelastic Technologies (SMST 2013)
    Datum konání21.05.2013-24.05.2013
    Místo konáníPraha
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaelectron microscopy ; failure analysis ; mechanical testing
    Vědní obor RIVBM - Fyzika pevných látek a magnetismus
    CEPGPP108/12/P111 GA ČR - Grantová agentura ČR
    GAP107/12/0800 GA ČR - Grantová agentura ČR
    7E11058 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaFZU-D - RVO:68378271 ; UT-L - RVO:61388998
    UT WOS000339010700053
    EID SCOPUS84904787401
    DOI10.1007/s11665-014-0916-9
    AnotaceA problem of random clinical failures of the braided esophageal NiTi stents has been addressed by performing physical simulation experiments on helical NiTi springs loaded in cyclic tension in air, water, and simulated biological fluid. Strains and stresses involved in spring deformation were analyzed through simulation by FEM implemented SMA model. It was found that the fatigue life of NiTi springs is significantly lower in fluids than in the air pointing toward the corrosion fatigue mechanism. There is, however, a fatigue limit roughly corresponding to the onset of martensitic transformation in the wire, which is not common for corrosion fatigue. It is proposed that surface TiO2 oxide cracking plays major role in that. Once the oxide layer on the NiTi wire surface fractures, typically during the first mechanical cycle, cracks in the oxide layer periodically open and close during subsequent mechanical cycling.