Počet záznamů: 1  

T1 mapping of myocardium in rats using self-gated golden-angle acquisition

  1. 1.
    SYSNO ASEP0579323
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevT1 mapping of myocardium in rats using self-gated golden-angle acquisition
    Tvůrce(i) Vitouš, Jiří (UPT-D)
    Jiřík, Radovan (UPT-D) RID, ORCID, SAI
    Stračina, T. (CZ)
    Hendrych, M. (CZ)
    Nádeníček, J. (CZ)
    Macíček, Ondřej (UPT-D) RID, ORCID, SAI
    Tian, Y. (US)
    Krátká, Lucie (UPT-D) RID, ORCID, SAI
    Dražanová, Eva (UPT-D) RID, ORCID, SAI
    Novaková, M. (CZ)
    Babula, P. (CZ)
    Panovský, R. (CZ)
    DiBella, E. (US)
    Starčuk jr., Zenon (UPT-D) RID, ORCID, SAI
    Celkový počet autorů14
    Zdroj.dok.Magnetic Resonance in Medicine. - : Wiley - ISSN 0740-3194
    Roč. 91, č. 1 (2024), s. 368-380
    Poč.str.13 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovacardiac ; fibrosis ; MRI ; quantification ; remodeling ; retrospective gating ; T1
    CEPGA22-10953S GA ČR - Grantová agentura ČR
    LM2018129 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LM2023050 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    EF18_046/0016045 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOpen access
    Institucionální podporaUPT-D - RVO:68081731
    UT WOS001077604100001
    EID SCOPUS85173930220
    DOI10.1002/mrm.29846
    AnotacePurpose: The aim of this study is to design a method of myocardial T1 quantification in small laboratory animals and to investigate the effects of spatiotemporal regularization and the needed acquisition duration. Methods: We propose a compressed-sensing approach to T1 quantification based on self-gated inversion-recovery radial two/three-dimensional (2D/3D) golden-angle stack-of-stars acquisition with image reconstruction performed using total-variation spatiotemporal regularization. The method was tested on a phantom and on a healthy rat, as well as on rats in a small myocardium-remodeling study. Results: The results showed a good match of the T1 estimates with the results obtained using the ground-truth method on a phantom and with the literature values for rats myocardium. The proposed 2D and 3D methods showed significant differences between normal and remodeling myocardium groups for acquisition lengths down to approximately 5 and 15 min, respectively. Conclusions: A new 2D and 3D method for quantification of myocardial T1 in rats was proposed. We have shown the capability of both techniques to distinguish between normal and remodeling myocardial tissue. We have shown the effects of image-reconstruction regularization weights and acquisition length on the T1 estimates.
    PracovištěÚstav přístrojové techniky
    KontaktMartina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178
    Rok sběru2025
    Elektronická adresahttps://onlinelibrary.wiley.com/doi/10.1002/mrm.29846
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.