Počet záznamů: 1
T1 mapping of myocardium in rats using self-gated golden-angle acquisition
- 1.
SYSNO ASEP 0579323 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název T1 mapping of myocardium in rats using self-gated golden-angle acquisition Tvůrce(i) Vitouš, Jiří (UPT-D)
Jiřík, Radovan (UPT-D) RID, ORCID, SAI
Stračina, T. (CZ)
Hendrych, M. (CZ)
Nádeníček, J. (CZ)
Macíček, Ondřej (UPT-D) RID, ORCID, SAI
Tian, Y. (US)
Krátká, Lucie (UPT-D) RID, ORCID, SAI
Dražanová, Eva (UPT-D) RID, ORCID, SAI
Novaková, M. (CZ)
Babula, P. (CZ)
Panovský, R. (CZ)
DiBella, E. (US)
Starčuk jr., Zenon (UPT-D) RID, ORCID, SAICelkový počet autorů 14 Zdroj.dok. Magnetic Resonance in Medicine. - : Wiley - ISSN 0740-3194
Roč. 91, č. 1 (2024), s. 368-380Poč.str. 13 s. Forma vydání Tištěná - P Jazyk dok. eng - angličtina Země vyd. US - Spojené státy americké Klíč. slova cardiac ; fibrosis ; MRI ; quantification ; remodeling ; retrospective gating ; T1 CEP GA22-10953S GA ČR - Grantová agentura ČR LM2018129 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LM2023050 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy EF18_046/0016045 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Způsob publikování Open access Institucionální podpora UPT-D - RVO:68081731 UT WOS 001077604100001 EID SCOPUS 85173930220 DOI 10.1002/mrm.29846 Anotace Purpose: The aim of this study is to design a method of myocardial T1 quantification in small laboratory animals and to investigate the effects of spatiotemporal regularization and the needed acquisition duration. Methods: We propose a compressed-sensing approach to T1 quantification based on self-gated inversion-recovery radial two/three-dimensional (2D/3D) golden-angle stack-of-stars acquisition with image reconstruction performed using total-variation spatiotemporal regularization. The method was tested on a phantom and on a healthy rat, as well as on rats in a small myocardium-remodeling study. Results: The results showed a good match of the T1 estimates with the results obtained using the ground-truth method on a phantom and with the literature values for rats myocardium. The proposed 2D and 3D methods showed significant differences between normal and remodeling myocardium groups for acquisition lengths down to approximately 5 and 15 min, respectively. Conclusions: A new 2D and 3D method for quantification of myocardial T1 in rats was proposed. We have shown the capability of both techniques to distinguish between normal and remodeling myocardial tissue. We have shown the effects of image-reconstruction regularization weights and acquisition length on the T1 estimates. Pracoviště Ústav přístrojové techniky Kontakt Martina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178 Rok sběru 2025 Elektronická adresa https://onlinelibrary.wiley.com/doi/10.1002/mrm.29846
Počet záznamů: 1