Počet záznamů: 1  

High-Resolution Residual Strain/Stress Measurements on Three Axis Neutron Diffractometer

  1. 1.
    SYSNO ASEP0551754
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JOstatní články
    NázevHigh-Resolution Residual Strain/Stress Measurements on Three Axis Neutron Diffractometer
    Tvůrce(i) Mikula, Pavol (UJF-V) RID, ORCID, SAI
    Šaroun, Jan (UJF-V) RID, ORCID, SAI
    Ryukhtin, Vasil (UJF-V) RID, ORCID, SAI
    Celkový počet autorů3
    Zdroj.dok.AMR - Advanced Materials Research. - : Scientific.Net - ISSN 1662-8985
    Roč. 1166, SEP (2021), s. 33-40
    Poč.str.8 s.
    Forma vydáníOnline - E
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaneutron diffraction ; Bragg diffraction optics ; residual stress measurement
    Vědní obor RIVBM - Fyzika pevných látek a magnetismus
    Obor OECDCondensed matter physics (including formerly solid state physics, supercond.)
    CEPEF16_013/0001794 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LM2018111 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Výzkumná infrastrukturaReactors LVR-15 and LR-0 II - 90120 - Centrum výzkumu Řež s.r.o.
    Způsob publikováníOmezený přístup
    Institucionální podporaUJF-V - RVO:61389005
    DOI10.4028/www.scientific.net/AMR.1166.33
    AnotaceFocusing 3-axis diffractometer set-up equipped with bent perfect crystal (BPC) monochromator and analyzer offers the sensitivity in determination of strains Dd/d < 10-4 in polycrystalline materials which is about one order of magnitude higher with respect to that of conventional 2-axis neutron scanners. It also offers possibility of line profile analysis for reasonable sample volumes and counting times. In this paper, the feasibility of using the 3-axis set-up even for measurements of rather large bulk polycrystalline samples with an acceptable resolution is presented. As the 3-axis set-up exploits focusing in real and momentum space, by a proper adjustment of the curvature of the analyzer, a high-resolution determination of the lattice changes can also be achieved even on large irradiated gauge volumes, though with a slightly relaxed resolution. It can be successfully exploited namely, in the strain/stress measurements on samples exposed to an external load, e.g. in tension/compression rig, in aging machine etc. In addition to the original performance where the analysis is carried out by rocking the BPC analyzer and the neutron signal registered by a point detector, a new alternative is offered which uses a fixed rocking angle position of the analyzer and the detector signal is registered by a one-dimensional position sensitive detector (PSD). This trick makes possible in some cases the elastic strain/stress measurements considerably faster and thus reduces the drawback of the time consuming step-by-step analysis.