Evaluation of Internal Cohesion of Plasma-Sprayed Coatings by Cavitation Test: Feasibility Study

  1. 1.
    SYSNO ASEP0538124
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JOstatní články
    NázevEvaluation of Internal Cohesion of Plasma-Sprayed Coatings by Cavitation Test: Feasibility Study
    Tvůrce(i) Mušálek, Radek (UFP-V) RID, ORCID
    Nardozza, E. (IT)
    Tesař, Tomáš (UFP-V) ORCID
    Medřický, Jan (UFP-V) RID
    Celkový počet autorů4
    Zdroj.dok.Acta Polytechnica. - : České vysoké učení technické - ISSN 1210-2709
    Roč. 27, Červen (2020), s. 73-78
    Poč.str.6 s.
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovaCavitation damage ; cohesion ; failure analysis ; plasma spray coatings
    Vědní obor RIVJP - Průmyslové procesy a zpracování
    Obor OECDMaterials engineering
    CEPGA19-10246S GA ČR - Grantová agentura ČR
    Způsob publikováníOpen access
    Institucionální podporaUFP-V - RVO:61389021
    DOI10.14311/APP.2020.27.0073
    AnotaceMechanical characterization of plasma-sprayed coatings at microscopic level representsa major challenge due to the presence of numerous inherent microstructural features such as cracks,pores, or splat boundaries, which complicate coatings characterization by conventional testing methods.Need for reliable testing of structural integrity of newly developed multiphase plasma-sprayed coatingsintroduced even more complexity to the testing. In this study, applicability of indirect vibratorycavitation test (adapted from ASTM G32 standard) for such testing was evaluated. Three plasma-sprayed coatings having distinctive microstructures were tested: i) conventional alumina coatingdeposited from coarse powder, ii) hybrid coating deposited by co-spraying of coarse alumina powderand fine yttria-stabilized zirconia (YSZ) suspension, and iii) compact alumina coating deposited fromfine ethanol-based suspension. Differences in the coatings internal cohesion were reflected in differentfailure mechanisms observed within the cavitation crater by scanning electron microscopy and meanerosion rates being i) 280μm/hour, ii) 97μm/hour and iii) 14μm/hour, respectively.