    NázevAnalysis of nucleotide pools in bacteria using HPLC-MS in HILIC mode
    Tvůrce(i) Zborníková, Eva (UOCHB-X) RID, ORCID
    Knejzlík, Zdeněk (UOCHB-X)
    Hauryliuk, V. (EE)
    Krásný, Libor (MBU-M) RID, ORCID
    Rejman, Dominik (UOCHB-X) RID, ORCID
    Číslo článku120161
    Zdroj.dok.Talanta. - : Elsevier - ISSN 0039-9140
    Roč. 205, Dec 1 (2019)
    Poč.str.10 s.
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovanucleotide ; HPLC-MS ; HILIC ; ppGpp ; stringent response ; Escherichia coli
    Vědní obor RIVCB - Analytická chemie, separace
    Obor OECDAnalytical chemistry
    Vědní obor RIV – spolupráceMikrobiologický ústav - Mikrobiologie, virologie
    CEPNV17-29680A GA MZd - Ministerstvo zdravotnictví
    GA15-11711S GA ČR - Grantová agentura ČR
    8F19006 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOpen access
    Institucionální podporaUOCHB-X - RVO:61388963 ; MBU-M - RVO:61388971
    UT WOS000485856500085
    EID SCOPUS85069720759
    DOI10.1016/j.talanta.2019.120161
    AnotaceNucleotides, nucleosides and their derivatives are present in all cells at varying concentrations that change with the nutritional, and energetic status of the cell. Precise measurement of the concentrations of these molecules is instrumental for understanding their regulatory effects. Such measurement is challenging due to the inherent instability of these molecules and, despite many decades of research, the reported values differ widely. Here, we present a comprehensive and easy-to-use approach for determination of the intracellular concentrations of >25 target molecular species. The approach uses rapid filtration and cold acidic extraction followed by high performance liquid chromatography (HPLC) in the hydrophilic interaction liquid chromatography (HILIC) mode using zwitterionic columns coupled with UV and MS detectors. The method reliably detects and quantifies all the analytes expected to be observed in the bacterial cell and paves the way for future studies correlating their concentrations with biological effects.
    PracovištěÚstav organické chemie a biochemie
    Kontaktasep@uochb.cas.cz ; Kateřina Šperková, Tel.: 232 002 584 ; Jana Procházková, Tel.: 220 183 418
    Rok sběru2020
    Elektronická adresahttps://www.sciencedirect.com/science/article/pii/S0039914019307878?via%3Dihub
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.