Počet záznamů: 1  

A Novel Time Lag Method for the Analysis of Mixed Gas Diffusion in Polymeric Membranes by On-Line Mass Spectrometry: Method Development and Validation.

  1. 1.
    SYSNO ASEP0493318
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevA Novel Time Lag Method for the Analysis of Mixed Gas Diffusion in Polymeric Membranes by On-Line Mass Spectrometry: Method Development and Validation.
    Tvůrce(i) Fraga, S. (PT)
    Monteleone, M. (IT)
    Lanč, M. (CZ)
    Esposito, E. (IT)
    Fuoco, A. (IT)
    Giorno, L. (IT)
    Pilnáček, K. (CZ)
    Friess, K. (CZ)
    Carta, M. (GB)
    McKeown, N.B. (GB)
    Izák, Pavel (UCHP-M) RID, ORCID, SAI
    Petrusová, Zuzana (UCHP-M) RID, ORCID, SAI
    Crespo, J. (PT)
    Braziniha, C. (PT)
    Jansen, J.C. (IT)
    Zdroj.dok.Journal of Membrane Science. - : Elsevier - ISSN 0376-7388
    Roč. 561, SEP 1 (2018), s. 39-58
    Poč.str.20 s.
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovagas separation membrane ; mixed gas diffusion ; time lag method
    Vědní obor RIVCI - Průmyslová chemie a chemické inženýrství
    Obor OECDChemical process engineering
    Institucionální podporaUCHP-M - RVO:67985858
    UT WOS000434713700005
    EID SCOPUS85047365249
    DOI10.1016/j.memsci.2018.04.029
    AnotaceA novel method to determine the individual diffusion coefficients of gases in a mixture during their permeation through polymeric membranes is described. The method was developed in two independent laboratories, using rubbery Pebax® and glassy Hyflon® AD60X membrane samples as standards, and validated using the Tröger s base containing Polymer of Intrinsic Microporosity, PIMEA-TB. Monitoring of the permeate composition in real time by a quadrupole mass spectrometer allowed the analysis of the permeation transient for gas mixtures. Two operation modes, either with a vacuum in the permeate and a direct connection to the mass spectrometer via a heated restriction, or using a sweeping gas and a heated capillary sample inlet, give excellent agreement with the traditional time lag method for single gases. A complete overview of the method development, identification of the critical parameters, instruments calibration, data elaboration and estimation of the experimental accuracy are provided. Validation with PIM-EA-TB, shows that the method can also successfully detect anomalous phenomena, related to pressure and concentration dependency of the transport properties, physical aging or penetrant-induced dilation. Rapid online analysis of the permeate composition makes the method also very suitable for routine mixed gas permeability measurements.
    PracovištěÚstav chemických procesů
    KontaktEva Jirsová, jirsova@icpf.cas.cz, Tel.: 220 390 227
    Rok sběru2019
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.