Počet záznamů: 1  

Scarf joint for replacement of decayed rafter ends: experimental investigation of bearing capacity under combined loading

  1. 1.
    SYSNO ASEP0492790
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevScarf joint for replacement of decayed rafter ends: experimental investigation of bearing capacity under combined loading
    Tvůrce(i) Kunecký, Jiří (UTAM-F) RID, SAI, ORCID
    Hasníková, Hana (UTAM-F) RID, SAI, ORCID
    Kloiber, Michal (UTAM-F) RID, ORCID, SAI
    Tippner, J. (CZ)
    Sebera, V. (CZ)
    Celkový počet autorů5
    Číslo článkuTRD-06-03
    Zdroj.dok.WCTE 2018 World Conference on Timber Engineering. Proceedings. - Seoul : National Institute of Forest Science, 2018 - ISBN 979-11-6019-235-3
    Poč.str.6 s.
    Forma vydáníNosič - C
    AkceWCTE 2018 World Conference on Timber Engineering
    Datum konání20.08.2018 - 23.08.2018
    Místo konáníSoul
    ZeměKR - Korejská republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.KR - Korejská republika
    Klíč. slovascarf joint ; rafter ; carpentry ; combined loading
    Vědní obor RIVJM - Inženýrské stavitelství
    Obor OECDConstruction engineering, Municipal and structural engineering
    CEPDG16P02M026 GA MK - Ministerstvo kultury
    LO1219 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    EID SCOPUS85058178557
    AnotaceThe paper deals with experimental investigation of bearing capacity of timber lapped scarf joint intended for replacement of rafter ends decayed by moisture-related attack. Such a connection is loaded predominantly in the combination of bending and compression because of a member role in the roof structure. Thus, three groups and a group of reference samples have been tested in different combinations of normal/bending force. The tests conducted to verify the design model of the connection show relatively high values (28%) of bearing capacity when compared to the full profile of old wood. Experiments show little influence of the compressive force on the bearing capacity in bending. High compressive normal force with negligible momentum is typical for rafters in medieval wooden structures and for the ones the joint is especially intended. The result allows the use of the joint in many cultural heritage sites where the value of the original material is significant and minimal interventions are required in order to preserve the original state of the building.
    PracovištěÚstav teoretické a aplikované mechaniky
    KontaktKulawiecová Kateřina, kulawiecova@itam.cas.cz, Tel.: 225 443 285
    Rok sběru2019
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.