Počet záznamů: 1  

UV degradation of styrene-butadiene rubber versus high density poly(ethylene) in marine conditions studied by infrared spectroscopy, micro indentation, and electron spin resonance imaging

  1. 1.
    SYSNO ASEP0492766
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevUV degradation of styrene-butadiene rubber versus high density poly(ethylene) in marine conditions studied by infrared spectroscopy, micro indentation, and electron spin resonance imaging
    Tvůrce(i) Šlouf, Miroslav (UMCH-V) RID, ORCID
    Pilař, Jan (UMCH-V) RID, ORCID
    Dybal, Jiří (UMCH-V) RID, ORCID
    Šloufová, I. (CZ)
    Michálková, Danuše (UMCH-V)
    Lukešová, Miroslava (UMCH-V) RID, ORCID
    Zgadzai, O. (IL)
    Blank, A. (IL)
    Filippov, Sergey K. (UMCH-V) RID, ORCID, SAI
    Zdroj.dok.Polymer Degradation and Stability. - : Elsevier - ISSN 0141-3910
    Roč. 156, October (2018), s. 132-143
    Poč.str.12 s.
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovastyrene-butadiene rubber ; high density poly(ethylene) ; electron spin resonance imaging
    Vědní obor RIVCD - Makromolekulární chemie
    Obor OECDPolymer science
    CEP8G15018 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    NV15-31269A GA MZd - Ministerstvo zdravotnictví
    LO1507 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUMCH-V - RVO:61389013
    UT WOS000448091400013
    EID SCOPUS85052496109
    DOI10.1016/j.polymdegradstab.2018.08.005
    AnotaceUV irradiation and thermal degradation were studied in marine conditions for styrene-butadiene rubber (SBR) and high density poly (ethylene) (HDPE) containing a Tinuvin® 770 hindered amine stabilizer. Electron spin resonance imaging (ESRI) was used to monitor degradation process in various depths and compare the polymers in terms of robustness to UV irradiation. In addition, both oxidative degradation and mechanical properties were studied by microscale methods, such as infrared microspectroscopy (IR) and microindentation hardness testing (MHI), enabling us to compare the material changes locally, i.e. both at the exposed surfaces and inside the samples. In SBR/Tin770 system, Tinuvin®770 stabilizer failed to protect the polymer matrix against photooxidation as clearly seen from IR/ATR spectra. The Weather-Ometer (WOM) aging resulted in strong oxidative degradation of both non-stabilized and stabilized SBR and caused remarkable changes in three regions of IR/ATR spectra. The strong photooxidative degradation was also manifested through the micromechanical properties of SBR/Tin770 systems. The change of the local properties was the same (within the standard deviations) for both stabilized and non-stabilized samples, which confirmed negligible stabilization efficiency of Tinuvin® 770 in the SBR system. In contrast to the SBR systems, similar experiments showed very dramatic stabilization effects in the HDPE/Tin770 system. ESR and 2D spectral-spatial ESRI directly proved the different degradation behavior of the two types of the composites: whereas in the SBR composites fast degradation was observed, high density poly (ethylene) showed much slower degradation. We attributed such striking difference to the modification of Tinuvin® 770 hindered amine stabilizer after vulcanization during preparation of SBR rubber, which apparently eliminated most of its protective activity.
    PracovištěÚstav makromolekulární chemie
    KontaktEva Čechová, cechova@imc.cas.cz ; Tel.: 296 809 358
    Rok sběru2019
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.