Počet záznamů: 1
Optical measurements of the mirrors and of the interferential filter of the Metis coronagraph on Solar Orbiter
- 1.
SYSNO ASEP 0485005 Druh ASEP C - Konferenční příspěvek (mezinárodní konf.) Zařazení RIV D - Článek ve sborníku Název Optical measurements of the mirrors and of the interferential filter of the Metis coronagraph on Solar Orbiter Tvůrce(i) Sandri, P. (IT)
Sarra, P. (IT)
Radaelli, P. (IT)
Morea, D. (IT)
Melich, Radek (UFP-V) RID
Berlicki, Arkadiusz (ASU-R) RID
Antonucci, E. (IT)
Castronuovo, M.M. (IT)
Fineschi, S. (IT)
Naletto, G. (IT)
Nicolini, G. (IT)
Romoli, M. (IT)Zdroj.dok. UV, X-Ray, and Gamma-Ray Space Instrumentation for Astronomy XX. - Bellingham : SPIE, 2017 - ISSN 0277-786X - ISBN 9781510612518 Rozsah stran 1039716/1-1039716/12 Poč.str. 12 s. Forma vydání Tištěná - P Akce Conference on UV, X-Ray, and Gamma-Ray Space Instrumentation for Astronomy /20./ Datum konání 06.08.2017 - 08.08.2017 Místo konání San Diego Země US - Spojené státy americké Typ akce WRD Jazyk dok. eng - angličtina Země vyd. US - Spojené státy americké Klíč. slova wavefront error ; mirrors ; interferential filter Vědní obor RIV BN - Astronomie a nebeská mechanika, astrofyzika Obor OECD Astronomy (including astrophysics,space science) Vědní obor RIV – spolupráce Ústav fyziky plazmatu - Elektronika a optoelektronika, elektrotechnika Institucionální podpora ASU-R - RVO:67985815 ; UFP-V - RVO:61389021 UT WOS 000417112900031 EID SCOPUS 85033460692 DOI 10.1117/12.2275416 Anotace The paper describes the wavefront error measurements of the concave ellipsoidal mirrors M1 and M2, of the concave spherical mirror M0 and of the flat interferential filter IF of the Metis coronagraph. Metis is an inverted occultation coronagraph on board of the ESA Solar Orbiter mission providing a broad-band imaging of the full corona in linearly polarized visible-light (580 - 640 nm) and a narrow-band imaging of the full corona in the ultraviolet Lyman alpha (121.6 nm). Metis will observe the solar outer atmosphere from a close distance to the Sun as 0.28 A.U. and from up to 35deg out-of-ecliptic. The measurements of wavefront error of the mirrors and of the interferential filter of Metis have been performed in a ISO5 clean room both at component level and at assembly level minimizing, during the integration, the stress introduced by the mechanical hardware. The wavefront error measurements have been performed with a digital interferometer for mirrors M0, M1 and M2 and with a Shack-Hartmann wavefront sensor for the interferential filter. Pracoviště Astronomický ústav Kontakt Radka Svašková, bibl@asu.cas.cz, Tel.: 323 620 326 Rok sběru 2018
Počet záznamů: 1