Počet záznamů: 1  

Relative Calibration of Galileo receivers within the Time Validation Facility (TVF)

  1. 1.
    SYSNO ASEP0457627
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevRelative Calibration of Galileo receivers within the Time Validation Facility (TVF)
    Tvůrce(i) Piriz, A. (ES)
    Rodriguez, D. (ES)
    Roldan, P. (ES)
    Mudrak, A. (NL)
    Bauch, A. (NL)
    Leute, J. (NL)
    Pánek, Petr (URE-Y) RID
    Kuna, Alexander (URE-Y) RID, RID, ORCID, SAI
    Zdroj.dok.Proceedings - Conference of the IEEE International Frequency Control Symposium and the European Frequency and Time Forum(FCS 2015). - Piscataway : IEEE, 2015 - ISBN 978-1-4799-8865-5
    Rozsah strans. 245-249
    Poč.str.5 s.
    Forma vydáníTištěná - P
    AkceFrequency Control Symposium & the European Frequency and Time Forum (FCS), 2015 Joint Conference of the IEEE International
    Datum konání12.04.2015 - 16.04.2015
    Místo konáníDenver
    ZeměUS - Spojené státy americké
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovareceiver calibration ; Galileo ; ground infrastructure
    Vědní obor RIVJB - Senzory, čidla, měření a regulace
    Institucionální podporaURE-Y - RVO:67985882
    EID SCOPUS84943329623
    DOI10.1109/FCS.2015.7138833
    AnotaceGMV is the prime contractor for the Time and Geodetic Validation Facility (TGVF) in the Galileo FOC phase (Full Operational Capability), a contract of the European Space Agency (ESA). Within the TGVF, the Time Validation Facility (TVF) is the subsystem in charge of steering Galileo System Time (GST) to UTC, among other duties. The TVF is operated at GMV headquarters near Madrid, Spain. Calibrated Galileo receivers are needed in the frame of TVF activities to, among other tasks, assess the UTC-GST offset broadcast in the Galileo navigation message. Absolute receiver calibration is a complex activity involving the availability of a signal simulator and of a calibrated reference antenna. An alternative data-based method to evaluate the Galileo receiver delay in E5 signals relative to GPS is also possible. The key feature of such method is the cancellation of the GPS and Galileo ionospheric delays when combining pseudoranges from two satellites with a close position in the sky. A software tool called gecal has been developed by GMV within the Galileo TVF, implementing such method and processing RINEX 3 observation files. Satellite positions are read from a SP3 orbit file. The tool allows the rapid E5 calibration of a new or existing Galileo receiver. This paper describes the tool and the calibration of three Galileo receivers used in the TVF. Galileo Signal-In-Space validation results obtained using such receivers are also presented
    PracovištěÚstav fotoniky a elektroniky
    KontaktPetr Vacek, vacek@ufe.cz, Tel.: 266 773 413, 266 773 438, 266 773 488
    Rok sběru2016
Počet záznamů: 1  