Počet záznamů: 1  

Alternative approach to study chemical processes for the preparation of .sup.10./sup.Be and .sup.26./sup.Al targets for AMS

  1. 1.
    SYSNO ASEP0571837
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevAlternative approach to study chemical processes for the preparation of 10Be and 26Al targets for AMS
    Tvůrce(i) Kameník, Jan (UJF-V) RID, ORCID, SAI
    Kučera, Jan (UJF-V) RID, ORCID, SAI
    Garba, Roman (UJF-V) ORCID, SAI, RID
    Celkový počet autorů3
    Zdroj.dok.Nuclear Instruments & Methods in Physics Research Section B. - : Elsevier - ISSN 0168-583X
    Roč. 535, FEB (2023), s. 200-204
    Poč.str.5 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovaSeparation ; Aluminum ; Beryllium ; AMS ; INAA ; Radiotracer
    Obor OECDAtomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)
    CEPEF16_019/0000728 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Výzkumná infrastrukturaCICRR - 90241 - Centrum výzkumu Řež s.r.o.
    Způsob publikováníOmezený přístup
    Institucionální podporaUJF-V - RVO:61389005
    UT WOS000975355400001
    EID SCOPUS85144321455
    DOI10.1016/j.nimb.2022.11.027
    AnotaceTwo established separation procedures for determination of in-situ produced 10Be and 26Al in quartz by accelerator mass spectrometry (AMS) were used for testing of radioactive 7Be tracer and instrumental neutron activation analysis (INAA) of Al as alternative methods for monitoring of the chemical process. Overall, both methods were efficient and could serve in development, calibration, and control of the separation process. An advantage of the 7Be radioactive tracer is the possibility of non-destructive measurement of Be during the experiment as well as direct measurement of the resin in the chromatographic column. INAA had the advantage of Al determination in separation sub-samples with variable matrix composition. Despite the use of solution obtained from loess leaching with a more complex composition than typically used dissolved quartz concentrate, both separation procedures proved sufficient robustness.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2024
    Elektronická adresahttps://doi.org/10.1016/j.nimb.2022.11.027
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.