Počet záznamů: 1  

Ultra-High-Frequency Electrocardiography

  1. 1.
    SYSNO ASEP0555150
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevUltra-High-Frequency Electrocardiography
    Tvůrce(i) Jurák, Pavel (UPT-D) RID, ORCID, SAI
    Leinveber, P. (CZ)
    Plešinger, Filip (UPT-D) RID, ORCID, SAI
    Čurila, K. (CZ)
    Viščor, Ivo (UPT-D) RID, ORCID, SAI
    Vondra, Vlastimil (UPT-D) RID, ORCID, SAI
    Matejková, M. (CZ)
    Znojilová, L. (CZ)
    Smíšek, Radovan (UPT-D) RID, ORCID, SAI
    Lipoldová, J. (CZ)
    Prinzen, F. W. (NL)
    Halámek, Josef (UPT-D) RID, ORCID, SAI
    Celkový počet autorů12
    Číslo článku93
    Zdroj.dok.2021 Computing in Cardiology (CinC), 48. - New York : IEEE, 2021 - ISSN 2325-8861 - ISBN 978-166547916-5
    Poč.str.4 s.
    Forma vydáníOnline - E
    AkceComputing in Cardiology 2021 /48./
    Datum konání12.09.2021 - 15.09.2021
    Místo konáníBrno
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaUltra High Frequency Electrocardiography ; ventricular dyssynchrony ; VDI monitor
    Vědní obor RIVFS - Lékařská zařízení, přístroje a vybavení
    Obor OECDMedical engineering
    CEPNU21-02-00584 GA MZd - Ministerstvo zdravotnictví
    FW03010434 GA TA ČR - Technologická agentura ČR
    Institucionální podporaUPT-D - RVO:68081731
    EID SCOPUS85124742337
    DOI10.23919/CinC53138.2021.9662795
    AnotaceBackground: We introduce a new technology that uses the ultra-high-frequency components (150-1000 Hz) of the electrocardiogram (UHF-ECG). Method: The UHF-ECG components represent weak signals generated by the depolarization of myocardial cells. The amplitude of UHF oscillations decreases with distance from the source. This property and the different timing of depolarization in the ventricles' volume enable mapping of the ventricular activation from the chest ECG leads. Because of a low signal-to-noise ratio of UHF oscillations, averaging must be performed. Single recording thus lasts 30 seconds and more. Results: UHF-ECG defines the time-spatial distribution of myocardial electrical activity. Corresponding numerical parameters are electrical dyssynchrony (e-DYS) and the duration of local depolarization (Vd). UHF ventricular depolarization maps present details of electrical activation. Conclusion: The UHF-ECG uses a new source of information originating in ventricular volumes that is different from the standard ECG. It provides information about the volumetric electrical activation associated with mechanical contraction. Its primary clinical utilization is in cardiac resynchronization, pacing optimization, and conduction system pacing.
    PracovištěÚstav přístrojové techniky
    KontaktMartina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178
    Rok sběru2022
    Elektronická adresahttps://ieeexplore.ieee.org/document/9662795