Počet záznamů: 1
Ceramic‐chromium hall sensors for environments with high temperatures and neutron radiation
- 1.
SYSNO ASEP 0543097 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Ceramic‐chromium hall sensors for environments with high temperatures and neutron radiation Tvůrce(i) Entler, Slavomír (UFP-V) ORCID
Šobáň, Zbyněk (FZU-D) RID, ORCID
Ďuran, Ivan (UFP-V) RID, ORCID
Kovařík, Karel (UFP-V) RID, ORCID
Výborný, Karel (FZU-D) RID, ORCID
Šebek, Josef (FZU-D) RID
Tazlaru, S. (CZ)
Střeleček, J. (CZ)
Sládek, Petr (UFP-V)Celkový počet autorů 9 Číslo článku 721 Zdroj.dok. Sensors. - : MDPI
Roč. 21, č. 3 (2021), s. 1-12Poč.str. 12 s. Jazyk dok. eng - angličtina Země vyd. CH - Švýcarsko Klíč. slova Chromium ; demo ; Fusion ; Hall sensors ; High temperature ; Metal ; Nanolayer ; Nu-clear ; Radiation ; Resistant Vědní obor RIV BL - Fyzika plazmatu a výboje v plynech Obor OECD Fluids and plasma physics (including surface physics) Vědní obor RIV – spolupráce Fyzikální ústav - Jaderná energetika CEP 8D15001 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy EF16_019/0000768 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LM2018110 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Způsob publikování Open access Institucionální podpora UFP-V - RVO:61389021 ; FZU-D - RVO:68378271 UT WOS 000615496300001 EID SCOPUS 85099664051 DOI 10.3390/s21030721 Anotace Ceramic‐chromium Hall sensors represent a temperature and radiation resistant alternative to Hall sensors based on semiconductors. Demand for these sensors is presently motivated by the ITER and DEMO nuclear fusion projects. The developed ceramic‐chromium Hall sensors were tested up to a temperature of 550 °C and a magnetic field of 14 T. The magnitude of the sensitivity of the tested sensor was 6.2 mV/A/T at 20 °C and 4.6 mV/A/T at 500 °C. The sensitivity was observed to be weakly dependent on a temperature above 240 °C with an average temperature coefficient of 0.014%/°C and independent of the magnetic field with a relative average deviation below the measurement accuracy of 0.086%. A simulation of a neutron‐induced transmutation was performed to assess changes in the composition of the chromium. After 5.2 operational years of the DEMO fusion reactor, the transmuted fraction of the chromium sensitive layer was found to be 0.27% at the most exposed sensor location behind the divertor cassette with a neutron fluence of 6.08 × 10 n/m . The ceramic‐chromium Hall sensors show the potential to be suitable magnetic sensors for environments with high temperatures and strong neutron radiation. 25 2 Pracoviště Ústav fyziky plazmatu Kontakt Vladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975 Rok sběru 2022 Elektronická adresa https://www.mdpi.com/1424-8220/21/3/721
Počet záznamů: 1