Počet záznamů: 1  

Ceramic‐chromium hall sensors for environments with high temperatures and neutron radiation

  1. 1.
    SYSNO ASEP0543097
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevCeramic‐chromium hall sensors for environments with high temperatures and neutron radiation
    Tvůrce(i) Entler, Slavomír (UFP-V) ORCID
    Šobáň, Zbyněk (FZU-D) RID, ORCID
    Ďuran, Ivan (UFP-V) RID, ORCID
    Kovařík, Karel (UFP-V) RID, ORCID
    Výborný, Karel (FZU-D) RID, ORCID
    Šebek, Josef (FZU-D) RID
    Tazlaru, S. (CZ)
    Střeleček, J. (CZ)
    Sládek, Petr (UFP-V)
    Celkový počet autorů9
    Číslo článku721
    Zdroj.dok.Sensors. - : MDPI
    Roč. 21, č. 3 (2021), s. 1-12
    Poč.str.12 s.
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaChromium ; demo ; Fusion ; Hall sensors ; High temperature ; Metal ; Nanolayer ; Nu-clear ; Radiation ; Resistant
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Obor OECDFluids and plasma physics (including surface physics)
    Vědní obor RIV – spolupráceFyzikální ústav - Jaderná energetika
    CEP8D15001 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    EF16_019/0000768 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LM2018110 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOpen access
    Institucionální podporaUFP-V - RVO:61389021 ; FZU-D - RVO:68378271
    UT WOS000615496300001
    EID SCOPUS85099664051
    DOI10.3390/s21030721
    AnotaceCeramic‐chromium Hall sensors represent a temperature and radiation resistant alternative to Hall sensors based on semiconductors. Demand for these sensors is presently motivated by the ITER and DEMO nuclear fusion projects. The developed ceramic‐chromium Hall sensors were tested up to a temperature of 550 °C and a magnetic field of 14 T. The magnitude of the sensitivity of the tested sensor was 6.2 mV/A/T at 20 °C and 4.6 mV/A/T at 500 °C. The sensitivity was observed to be weakly dependent on a temperature above 240 °C with an average temperature coefficient of 0.014%/°C and independent of the magnetic field with a relative average deviation below the measurement accuracy of 0.086%. A simulation of a neutron‐induced transmutation was performed to assess changes in the composition of the chromium. After 5.2 operational years of the DEMO fusion reactor, the transmuted fraction of the chromium sensitive layer was found to be 0.27% at the most exposed sensor location behind the divertor cassette with a neutron fluence of 6.08 × 10 n/m . The ceramic‐chromium Hall sensors show the potential to be suitable magnetic sensors for environments with high temperatures and strong neutron radiation. 25 2
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2022
    Elektronická adresahttps://www.mdpi.com/1424-8220/21/3/721
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.