Počet záznamů: 1  

Recent improvement of the design of the ITER steady-state magnetic sensors

  1. 1.
    SYSNO ASEP0538555
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevRecent improvement of the design of the ITER steady-state magnetic sensors
    Tvůrce(i) Entler, Slavomír (UFP-V) ORCID
    Kocan, M. (FR)
    Ďuran, Ivan (UFP-V) RID, ORCID
    Vayakis, G. (FR)
    Lucca, G. (ES)
    Vigano, F. (IT)
    Cantu, P. (FR)
    Celkový počet autorů7
    Zdroj.dok.IEEE Transactions on Plasma Science. - : Institute of Electrical and Electronics Engineers - ISSN 0093-3813
    Roč. 46, č. 5 (2018), s. 1276-1280
    Poč.str.5 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaCalibration ; Hall effect devices ; iter ; magnetic field measurement ; measurement errors
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Obor OECDFluids and plasma physics (including surface physics)
    Způsob publikováníOmezený přístup
    Institucionální podporaUFP-V - RVO:61389021
    UT WOS000431521700031
    EID SCOPUS85041689749
    DOI10.1109/TPS.2018.2795243
    AnotaceA recent improvement of the design of the ITER outer vessel steady-state magnetic field sensors (OVSS) is presented. OVSS features a pair of Hall sensors with a sensing layer made of bismuth. Sixty OVSS will be installed on the ITER vacuum vessel outer skin to perform an absolute measurement of magnetic field. The bismuth Hall sensor measurement is temperature dependent, and the maximum allowed OVSS error of 4-mT limits the error of the measurement of the Hall sensor temperature by an on-board thermocouple to be less than 0.28 °C. This error consists of the temperature difference between the thermocouple and Hall sensors, thermocouple calibration error, and thermocouple measurement error. The improved design of the sensor housing reduces the temperature difference between the thermocouple and the Hall sensors bellow 0.04 °C. Procedures of the calibration prior installation and in situ calibration will allow calibrating the on-board thermocouple with the error less than 0.06 °C. The thermocouple measurement error limit was determined as 0.27 °C in which case OVSS meets the maximum allowed error.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2021
    Elektronická adresahttps://ieeexplore.ieee.org/document/8278837
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.