Počet záznamů: 1  

Voltammetric characterization of boron-doped diamond electrodes for electroanalytical applications

  1. 1.
    SYSNO ASEP0536164
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevVoltammetric characterization of boron-doped diamond electrodes for electroanalytical applications
    Tvůrce(i) Řeháček, V. (SK)
    Hotový, I. (SK)
    Marton, M. (SK)
    Mikolášek, M. (SK)
    Michniak, P. (SK)
    Vincze, A. (SK)
    Kromka, Alexander (FZU-D) RID, ORCID, SAI
    Vojs, M. (SK)
    Celkový počet autorů8
    Číslo článku114020
    Zdroj.dok.Journal of Electroanalytical Chemistry. - : Elsevier - ISSN 1572-6657
    Roč. 862, Apr (2020), s. 1-9
    Poč.str.9 s.
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaboron-doped diamond ; electrode kinetics ; electroanalysis ; voltammetry ; surface treatment ; Bismuth film
    Vědní obor RIVCG - Elektrochemie
    Obor OECDAnalytical chemistry
    Způsob publikováníOmezený přístup
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000525903900035
    EID SCOPUS85080956059
    DOI10.1016/j.jelechem.2020.114020
    AnotaceThe boron-doped diamond (BDD) electrodes prepared by chemical vapor deposition on alumina substrates were electrochemically characterized by cyclic voltammetry. The influence was investigated of the boron dopant concentration, surface termination as well as chemical surface treatment on the kinetics of the electrode reaction. The effect of surface conditions of the boron-doped diamond electrodes on the kinetics of the electrodeposition of bismuth film was investigated for electrochemical applications in which bismuth film electrodes are utilized. A favourable effect of the cleaning procedures was proved, especially for the oxygen plasma-treated BDD electrode with a higher content of boron in alkaline solution. The anodic current response increased by 109% as compared with as-grown BDD. The effect of the quality of bismuth film on analytical performance of the voltammetric sensor was verified in simultaneous analysis of heavy metals (Pb, Cd and Zn) by anodic stripping voltammetry.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2021
    Elektronická adresahttps://doi.org/10.1016/j.jelechem.2020.114020