Počet záznamů: 1  

Examples of Using of Electrochemical Detection at Pencil Graphite Electrode with Enzymatic Labeling for Analysis of Nucleotide Sequence

  1. 1.
    SYSNO ASEP0506711
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevExamples of Using of Electrochemical Detection at Pencil Graphite Electrode with Enzymatic Labeling for Analysis of Nucleotide Sequence
    Tvůrce(i) Plucnara, Medard (BFU-R) ORCID
    Haroniková, Lucia (BFU-R)
    Špaček, Jan (BFU-R) ORCID
    Havran, Luděk (BFU-R) RID, ORCID
    Horáková, Petra (BFU-R)
    Pivoňková, Hana (BFU-R) ORCID
    Ecsin, E. (TR)
    Erdem, A. (TR)
    Fojta, Miroslav (BFU-R) RID, ORCID
    Celkový počet autorů9
    Zdroj.dok.XXXV. Moderní elektrochemické metody. Sborník přednášek mezinárodní odborné konference. - Ústí nad Labem : Srsenová Lenka - Best Servis, 2015 / Navrátil Tomáš ; Fojta M. ; Schwarzová Karolína - ISBN 978-80-905221-3-8
    Rozsah stranč. 2015 (2015), s. 175-179
    Poč.str.5 s.
    Forma vydáníTištěná - P
    AkceModerní elektrochemické metody /35./
    Datum konání18.05.2015 - 22.05.2015
    Místo konáníJetřichovice
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovadna hybridization ; Enzymatic labeling ; Alkaline phosphatase
    Vědní obor RIVCG - Elektrochemie
    Obor OECDElectrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
    CEPGBP206/12/G151 GA ČR - Grantová agentura ČR
    Institucionální podporaBFU-R - RVO:68081707
    UT WOS000358792900040
    AnotaceMany examples of utilization of enzymatic labeling for DNA sequence analysis has been described in literature so far. Some of them involve hybridization with complementary biotinylated probe, while others use incorporation of biotinylated nucleotides into DNA strand by DNA polymerases. Common approach is then binding of streptavidine-enzyme conjugates to biotin tags and incubation with substrate, which is converted to detectable product. Here, two recent applications using this principle are described for the detection of PCR amplicons and for SNP typing. Both techniques are combined with detection at pencil graphite electrodes.
    PracovištěBiofyzikální ústav
    KontaktJana Poláková, polakova@ibp.cz, Tel.: 541 517 244
    Rok sběru2020
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.