Ultrasound exfoliation of graphite in biphasic liquid systems containing ionic liquids: A study on the conditions for obtaining large few-layers graphene

  1. 1.
    SYSNO ASEP0501214
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevUltrasound exfoliation of graphite in biphasic liquid systems containing ionic liquids: A study on the conditions for obtaining large few-layers graphene
    Tvůrce(i) Godoy, A. P. (BR)
    Ecorchard, Petra (UACH-T) SAI, RID, ORCID
    Beneš, Hynek (UMCH-V) RID, ORCID
    Tolasz, Jakub (UACH-T) RID, ORCID, SAI
    Smržová, Darina (UACH-T) ORCID, SAI, RID
    Seixas, L. (BR)
    Pedrotti, J. J. (BR)
    de Souza, E. A.T. (BR)
    El Seoud, O. A. (BR)
    Donato, R. K. (BR)
    Celkový počet autorů10
    Zdroj.dok.Ultrasonics Sonochemistry. - : Elsevier - ISSN 1350-4177
    Roč. 55, JUL (2019), s. 279-288
    Poč.str.10 s.
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovaBiphasic liquid system ; Cavitation-based emulsification ; Graphene ; Ionic liquids ; Liquid phase exfoliation
    Vědní obor RIVCA - Anorganická chemie
    Obor OECDInorganic and nuclear chemistry
    Vědní obor RIV – spolupráceÚstav makromolekulární chemie - Makromolekulární chemie
    CEPLM2015073 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GA17-08273S GA ČR - Grantová agentura ČR
    Způsob publikováníOpen access s časovým embargem (01.07.2020)
    Institucionální podporaUACH-T - RVO:61388980 ; UMCH-V - RVO:61389013
    UT WOS000470047800030
    EID SCOPUS85060749366
    DOI10.1016/j.ultsonch.2019.01.016
    AnotaceHerein we describe a successful protocol for graphite exfoliation using a biphasic liquid system (water/dichloromethane, DCM) containing ionic liquids (ILs, 1,3-dibenzylimidazolium benzoate- and 1-naphthoate). The use of (surface active) IL and sonication led to stable DCM/water (O/W) emulsion, which enhanced graphene formation, suppressed its re-aggregation and decreased shear/cavitation damage. The O/W emulsion stabilization by the ILs was studied by dynamic light scattering (DLS), whereas their interaction with the graphene sheets were described by Density Functional Theory (DFT) calculations. Moreover, a comprehensive investigation on cavitation-based exfoliation in the O/W systems was performed to assess the importance of operational parameters, including, the type of ultrasound processor, ultrasound power and insonation, and the influence of the exfoliation medium.