Počet záznamů: 1
New detectors for low-energy BSE
- 1.
SYSNO ASEP 0460204 Druh ASEP C - Konferenční příspěvek (mezinárodní konf.) Zařazení RIV D - Článek ve sborníku Název New detectors for low-energy BSE Tvůrce(i) Lalinský, Ondřej (UPT-D) RID, ORCID, SAI
Schauer, Petr (UPT-D) RID, SAI, ORCID
Kučera, M. (CZ)
Hanuš, M. (CZ)
Lučeničová, Z. (CZ)Celkový počet autorů 5 Zdroj.dok. Proceedings of the 15th International Seminar on Recent Trends in Charged Particle Optics and Surface Physics Instrumentation. - Brno : Institute of Scientific Instruments CAS, 2016 / Mika Filip - ISBN 978-80-87441-17-6 Rozsah stran s. 34-35 Poč.str. 2 s. Forma vydání Tištěná - P Akce International Seminar on Recent Trends in Charged Particle Optics and Surface Physics Instrumentation /15./ Datum konání 29.05.2016 - 03.06.2016 Místo konání Skalský dvůr Země CZ - Česká republika Typ akce WRD Jazyk dok. eng - angličtina Země vyd. CZ - Česká republika Klíč. slova BSE detector ; cathodoluminescence ; low-energy electron ; scintillator Vědní obor RIV JA - Elektronika a optoelektronika, elektrotechnika CEP TE01020118 GA TA ČR - Technologická agentura ČR GA16-05631S GA ČR - Grantová agentura ČR LO1212 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy ED0017/01/01 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Institucionální podpora UPT-D - RVO:68081731 UT WOS 000391254000015 Anotace Backscattered electrons (BSE) are mostly used to study the specimen’s topography. Nowadays, low energy (units of keV) electron beam imaging is often necessary for example for the research of nanomaterials, biomaterials or semiconductors. Because BSE detectors are mostly non-accelerating or low-accelerating, electrons with approximately the same energy as primary beam (PB) have to be detected. Therefore, BSE detectors need to become optimized for such low-energy electrons. For the scintillation detectors, the biggest problem probably lies in the scintillator. Semiconductor detectors aren’t studied in this work. Cerium activated bulk single crystals of yttrium aluminium garnet (YAG:Ce)Ce(X):Y(3-X)Al(5)O(12) are widely used as scintillators for the detection of high-energy backscattered electrons (BSE). However, commonly used YAG:Ce single crystal strongly loses its light yield (LY) with the decrease of the PB energy. As possible available alternatives for this application, bulk single crystals of yttrium aluminium perovskite (YAP:Ce) Ce(x)Y(1-X)AlO(3) and CRY018 can be predicted. However, similar LY drop can be expected also with these scintillators. Pracoviště Ústav přístrojové techniky Kontakt Martina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178 Rok sběru 2017 Elektronická adresa http://www.trends.isibrno.cz/
Počet záznamů: 1