The effect of high-flux H plasma exposure with simultaneous transient heat loads on tungsten surface damage and power handling

  1. 1.
    SYSNO ASEP0439649
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevThe effect of high-flux H plasma exposure with simultaneous transient heat loads on tungsten surface damage and power handling
    Tvůrce(i) van Eden, G.G. (NL)
    Morgan, T.W. (NL)
    van der Meiden, H.J. (NL)
    Matějíček, Jiří (UFP-V) RID, ORCID
    Chráska, Tomáš (UFP-V) RID, ORCID
    Wirtz, M. (DE)
    De Temmerman, G. (FR)
    Zdroj.dok.Nuclear Fusion. - : Institute of Physics Publishing - ISSN 0029-5515
    Roč. 54, č. 12 (2014), s. 123010-123010
    Poč.str.11 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.AT - Rakousko
    Klíč. slovaELMs ; tungsten ; thermal shock ; melting ; surface analysis ; laser ; hydrogen
    Vědní obor RIVJG - Hutnictví, kovové materiály
    CEPGA14-12837S GA ČR - Grantová agentura ČR
    Institucionální podporaUFP-V - RVO:61389021
    UT WOS000345579800016
    EID SCOPUS84914693453
    DOI10.1088/0029-5515/54/12/123010
    AnotaceThe performance of the full-W ITER divertor may be significantly affected by the interplay between steady-state plasma exposure and transient events. To address this issue, the effect of a high-flux H plasma on the thermal shock response of W to ELM-like transients has been investigated. Transient heating of W targets is performed by means of a high-power Nd:YAG laser with simultaneous exposure to H plasma in the linear device Magnum-PSI. The effects of simultaneous exposure to laser and plasma have been compared to those sequentially and to laser only. Transient melting is found to be aggravated during plasma exposure and to occur at lower heat flux parameters. Roughness and grain growth are observed to be driven by peak temperature, rather than by the loading conditions. The temperature evolution of the W surface under a series of transients is recorded by fast infrared thermography. By accounting for changes in the reflectivity at the damaged surface as measured by ellipsometry