Počet záznamů: 1
Electrophoretic Determination of Symmetric and Asymmetric Dimethylarginine in Human Blood Plasma with Whole Capillary Sample Injection
- 1.
SYSNO ASEP 0541396 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Electrophoretic Determination of Symmetric and Asymmetric Dimethylarginine in Human Blood Plasma with Whole Capillary Sample Injection Tvůrce(i) Tůma, P. (CZ)
Sommerová, B. (CZ)
Koval, Dušan (UOCHB-X) RID, ORCID
Couderc, F. (FR)Číslo článku 2970 Zdroj.dok. International Journal of Molecular Sciences. - : MDPI
Roč. 22, č. 6 (2021)Poč.str. 14 s. Jazyk dok. eng - angličtina Země vyd. CH - Švýcarsko Klíč. slova amino acid ; capillary coating ; capillary electrophoresis ; clinical analysis ; contactless conductivity detection ; dimethylarginines ; sample treatment ; stacking Obor OECD Analytical chemistry Způsob publikování Open access Institucionální podpora UOCHB-X - RVO:61388963 UT WOS 000645825400001 EID SCOPUS 85102454435 DOI 10.3390/ijms22062970 Anotace Asymmetric and symmetric dimethylarginines are toxic non-coded amino acids. They are formed by post-translational modifications and play multifunctional roles in some human diseases. Their determination in human blood plasma is performed using capillary electrophoresis with contactless conductivity detection. The separations are performed in a capillary covered with covalently bonded PAMAPTAC polymer, which generates anionic electroosmotic flow and the separation takes place in the counter-current regime. The background electrolyte is a 750 mM aqueous solution of acetic acid with pH 2.45. The plasma samples for analysis are treated by the addition of acetonitrile and injected into the capillary in a large volume, reaching 94.5% of the total volume of the capillary, and subsequently subjected to electrophoretic stacking. The attained LODs are 16 nm for ADMA and 22 nM for SDMA. The electrophoretic resolution of both isomers has a value of 5.3. The developed method is sufficiently sensitive for the determination of plasmatic levels of ADMA and SDMA. The determination does not require derivatization and the individual steps in the electrophoretic stacking are fully automated. The determined plasmatic levels for healthy individuals vary in the range 0.36–0.62 µM for ADMA and 0.32–0.70 µM for SDMA. Pracoviště Ústav organické chemie a biochemie Kontakt asep@uochb.cas.cz ; Kateřina Šperková, Tel.: 232 002 584 ; Jana Procházková, Tel.: 220 183 418 Rok sběru 2022 Elektronická adresa https://doi.org/10.3390/ijms22062970
Počet záznamů: 1