Počet záznamů: 1  

High temperature low cycle fatigue of superalloy Inconel 738LC

  1. 1.
    SYSNO ASEP0093510
    Druh ASEPA - Abstrakt
    Zařazení RIVZáznam nebyl označen do RIV
    Zařazení RIVNení vybrán druh dokumentu
    NázevHigh temperature low cycle fatigue of superalloy Inconel 738LC
    Překlad názvuVysokoteplotní nízkocyklová únava superslitiny Inconel 738LC
    Tvůrce(i) Obrtlík, Karel (UFM-A) RID, ORCID
    Chlupová, Alice (UFM-A) RID, ORCID
    Petrenec, Martin (UFM-A)
    Polák, Jaroslav (UFM-A) RID, ORCID
    Zdroj.dok.Programme and The Book of Abstracts. - Belgrade : Institute of Technical Sciences of SASA, 2007 - ISBN 978-86-80321-11-0
    S. 138-138
    Poč.str.1 s.
    AkceYugoslav Conference on Advanced Materials /2./
    Datum konání15.09.1997-19.09.1997
    Místo konáníHerceg Novi
    ZeměYU - YU
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.CS - CS
    Klíč. slovaLow cycle fatigue ; Inconel 738LC ; strain localization ; fatigue life curve
    Vědní obor RIVJL - Únava materiálu a lomová mechanika
    CEP1QS200410502 GA AV ČR - Akademie věd
    GA106/07/1507 GA ČR - Grantová agentura ČR
    GP106/05/P521 GA ČR - Grantová agentura ČR
    CEZAV0Z20410507 - UFM-A (2005-2011)
    AnotaceCylindrical specimens of cast polycrystalline nickel base superalloy Inconel 738LC were cyclically strained under total strain control at 23, 500, 700 and 800 °C to fracture. Cyclic hardening/softening curves, cyclic stress-strain curves, and fatigue life curves were obtained at four temperatures. Surface relief was studied in specimens fatigued to failure using scanning electron microscopy. Cyclic hardening/softening behaviour depends both on temperature and strain amplitude. Low amplitude straining was characterised by saturation of the stress amplitude. In high amplitude straining a pronounced hardening was found which was followed by saturation at room temperature or tendency to it at 700 and by cyclic softening at 800 °C. The cyclic stress-strain curves can be fitted by power law. They are shifted to lower stresses with increasing temperature. Fatigue life curves can be approximated by the Manson-Coffin and Basquin laws. Slip markings were detected on specimen surface at all test temperatures. When temperature increases the density of slip markings decreases and the Manson-Coffin and Basquin curves are shifted to lower lives.
    PracovištěÚstav fyziky materiálu
    KontaktYvonna Šrámková, sramkova@ipm.cz, Tel.: 532 290 485
    Rok sběru2008
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.